• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.58.2019.tde-04102022-115049
Documento
Autor
Nombre completo
Barbara Braga Jobim
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2019
Director
Tribunal
Cruz Filho, Antonio Miranda da (Presidente)
Correr Sobrinho, Lourenço
Rached Junior, Fuad Jacob Abi
Sousa Neto, Manoel Damião de
Título en portugués
Efeito do tempo de armazenamento sobre as propriedades físico-químicas do cimento endodôntico AH Plus
Palabras clave en portugués
Cimento endodôntico
Endodontia
Propriedades físico-químicas
Resumen en portugués
O objetivo do presente estudo foi avaliar o efeito do tempo de armazenamento sobre as propriedades físico-químicas do cimento endodôntico AH Plus. Avaliou-se ainda, por meio de testes complementares, os elementos químicos presentes na amostra referente ao primeiro uso da pasta B. Os testes de escoamento e tempo de endurecimento foram conduzidos em conformidade com as Especificações nº 57 da ANSI/ADA. Os testes de solubilidade e alteração dimensional seguiram as modificações propostas por Carvalho-Júnior et al. (2007). Foram utilizados quatro caixas de cimento (C1, C2, C3 e C4), com as quais realizaram-se a aleatorização, para que todos os cimentos fossem utilizados em todos os testes até o final do experimento. Analisaram-se as propriedades de tempo de endurecimento, escoamento, solubilidade e alteração dimensional, em quatro momentos: logo que aberto (T0), após 30 (T30), 90 (T90) e 360 (T360) dias após a abertura. Os dados foram analisados por meio dos testes ANOVA one-way e Tukey (α=0,05). A média do tempo de endurecimento foi de 515,10 ± 54,89 minutos. No entanto, T0 ultrapassou os 10% estabelecidos como variação máxima pela ANSI/ADA (596,80 ± 7,05). T0 foi estatisticamente diferente (p≤0,01) de T30, T90 e T360. A propriedade de escoamento atendeu às normas ANSI/ADA (≥20 mm). Esta propriedade diminui significativamente (p≤0,05) com o passar do tempo. A solubilidade não excedeu 3% de massa no período de análise. A expansão do cimento (0,94%±0,12), apesar de ter diminuído com o tempo, não atendeu às especificações da ANSI/ADA. Na amostra inicial da pasta B, foram detectados todos os componentes dessa pasta com predominância de óleo de silicone. Com exceção da alteração dimensional, as propriedades do cimento AH Plus aqui avaliadas não sofrem alterações no período de 360 dias de armazenamento.
Título en inglés
Effect of storage time on the physico-chemical properties of endodontic sealer AH Plus
Palabras clave en inglés
Endodontic cement
Endodontics
Physicochemical properties
Resumen en inglés
The aim of the present study was to evaluate the effect of storage time on the physico-chemical properties of endodontic sealer AH Plus. The chemical elements present in the first part of paste B were further evaluated by complementary tests. Flow and setting time tests were conducted in accordance with ANSI/ADA Specifications No 57. Solubility and dimensional change tests followed the modifications proposed by Carvalho-Júnior et al. (2007). Four sealers boxes were used (C1, C2, C3 and C4), which randomization was performed so that all sealers were used in all tests until the end of the experiment. The properties of setting time, flow, solubility and dimensional change were analyzed at four moments: once it was opened (T0) after 30 days of open (T30), after 90 days of open (T90) and after 360 days (T360). Data were analyzed by ANOVA one-way and Tukey tests (α=0,05). The average setting time was 515.10 ± 54.89 minutes. However, in T0, it exceeded the 10% established as maximum variation by ANSI / ADA (596.80 ± 7.05). T0 was statistically different (P≤0. 01) from T30, T90 and T360. The AH Plus flow complied with ANSI / ADA standards (≥20 mm). This property significantly decreased (P≤0.05) over time. Solubility did not exceed 3% of mass in the analysis period. Sealer expansion (0.94% ± 0.12), although decreasing over time, did not met ANSI / ADA specifications. In the initial sample of paste B, all components of this paste were present, but the predominance of silicone oil were detected. With the exception of dimensional change, the evaluated properties of AH Plus do not change during the 360 days of storage.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2022-10-05
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.