• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.58.1985.tde-26022024-103453
Document
Auteur
Nom complet
Wilson Abrão
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 1985
Directeur
Jury
Roselino, Ruy Barbosa (Président)
Campos, Geraldo Maia
Marchetti, Romeu Marcos
Titre en portugais
Influência da condição de armazenamento de moldes de mercaptana nas alterações dimensionais lineares ocorridas nos modelos de gesso-pedra melhorado
Mots-clés en portugais
Gesso-pedra melhorado
Moldes de mercaptana
Ponte-fixa
Reabilitação oral
Resumé en portugais
O objetivo da pesquisa, própria desta Dissertação, foi avaliar, por um método indireto, as alterações dimensionais lineares, de 50 modelos de gesso-pedra melhorado, após a interação com moldes de uma mercaptana, armazenados em duas condições diferentes (A e B). O método indireto proposto foi configurado por uma ponte-fixa esquemática assentada num modelo-mestre de aço inoxidável. Essa ponte-fixa foi obtida por enceramento direto no modelo-mestre, o qual apresentava dois suportes para coroas totais e espaço para um pôntico simulado, representado por uma barra seccionada. Cada uma das secções dessa barra unia-se a um dos retentores. O espaço entre as hemisseções foi medido pelo microscópio de mensuraçao, sendo avaliado em 0,501 milímetro, valor este dado pela média de 5 leitura, com aproximação de 1 micrometro. Esse valor médio de 0,501 milímetro serviu como parâmetro para determinar quais os gessos e qual a condição de armazenamento dos moldes que apresentavam o melhor comportamento, quando a mesma ponte-fixa era assentada nos modelos experimentais. Esse comportamento era tanto melhor quanto mais próximo o valor do espaço entre as hemissecções e o valor linear médio dado pelo parâmetro. Para as duas condições de armazenamento - A, por 5 minutos à temperatura de 25°C e 55 por cento de umidade relativa e B, por 40 minutos à temperatura de 37°C e 100 por cento de umidade relativa - a análise estatística apontou haver significância entre moldes, como também entre gessos. Assim, a condição de armazenamento dos moldes teve influência na alteração linear dos modelas de gesso, sendo que a condição de armazenamento B influiu mais positivamente para se conseguirem modelos de gessos com menor alteração linear, em comparação com a condição A. Os gessos Geo Stone, Durone e Glastone tiveram comportamento mais uniforme e mais próximos do valor médio dado pelo parâmetro. O gesso Troquel Stone e o gesso Vel Mix tiveram comportamentos diferentes entre si: enquanto o gesso Troquel Stone apresentou expansão, o gesso Vel Mix apresentou contração, quando se passa da condição A para a condição B de armazenamento dos moldes de mercaptana empregada.
Titre en anglais
Influence of the storage condition of mercaptan molds on the linear dimensional changes occurring in the improved plaster-stone models
Mots-clés en anglais
Fixed bridge
Improved stone plaster
Mercaptan molds
Oral rehabilitation
Resumé en anglais
The objective of the present study was to evaluate by an indirect method the linear dimensional alterations of 50 improved stone molds after interaction with a mercaptan mold and stored under two different types of conditions (A and B). The proposed indirect method consisted of a schematic fixed bridge fitted in a stainless steel master die. This fixed bridge was obtained by direct waxing into the master die, which had two abutments for full crowns and space for a simulated pontic represented by a sectioned bar. Each section of this bar was joined to one of the retainers. The space between the hemisections was measured with a measuring microscope and was estimated to be 0.501 mm, which was the average value of 5 readings with 1 um approximation. This mean 0.501 mm value was used as a parameter to determine which improved stone and which condition of mold storage behaved best when the same fixed bridge was fitted in the experimental molds. The closer the value of the space between hemisections to the linear value given by the parameter, the better the behavior of the materials. For the two types of storage conditions - A, 5 minutes at 25°C and 55 per cent relative humidity, and B, 40 minutes at 37°C and 100 per cent relative humidity - statistical analysis showed significant differences between molds as well as between stones. Thus, the type of mold storage influenced the linear alteration of the stone molds, with the B situation having a more positive action in terms of the possibility of obtaining stone molds with small linear alteration than the A situation. The Geo Stone, Durone and Glastone stones had a more uniform behavior and were closer to the mean value of the parameter. Troquel Stone and Vel Mix behaved in opposite ways: Troquel Stone showed expansion, whereas Vel Mix showed contraction when condition A was replaced with condition B for the storage of the mercaptan molds employed.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
000717519.pdf (4.21 Mbytes)
Date de Publication
2024-02-26
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.