• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.58.2018.tde-23022018-140530
Document
Author
Full name
Cecilia Vilela Matias Vasconcelos
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2017
Supervisor
Committee
Tirapelli, Camila (President)
Caneppele, Taciana Marco Ferraz
Corona, Silmara Aparecida Milori
Silva, Rodivan Braz da
Title in Portuguese
Odontologia digital: estudo da concordância entre avaliação clínica e fotográfica de restaurações de resina composta
Keywords in Portuguese
Dentística operatória; Fotografia; Odontologia digital; Pesquisa clínica; Resina composta
Abstract in Portuguese
O presente estudo teve por objetivo observar os níveis de concordância entre a avaliação clínica e fotográfica digital no diagnóstico de desempenho de restaurações posteriores (Classe I e Classe II) em resina composta. As avaliações clínicas foram feitas por dois examinadores (C1 e C2) calibrados (e-calib) usando critérios da Fédération Dentaire Internationale (FDI) considerando propriedades estéticas, funcionais e biológicas. Em cada momento de avaliação clínica, uma fotografia digital padronizada de cada restauração foi realizada. Dois examinadores digitais (D1 e D2), igualmente calibrados e usando os mesmos critérios avaliaram todas as imagens obtidas nas avaliações clínicas. Os dados foram analisados com Coeficiente de Cohen Kappa e teste não paramétrico de Kruskal-Wallis e o teste de Dunn de comparação múltipla, com nível de significância de 5%. Comparações intra (mesmo método) e inter (métodos diferentes) examinadores foram feitas. Os resultados revelaram que os níveis de concordância variaram de "Perfeito" a "Justo". Houve diferença significante (p < 0.05) intra-examinadores; entre C1 e C2 para o manchamento marginal; entre D1 e D2 para brilho superficial, estabilidade de cor e translucidez, forma anatômica, e fratura do material e retenção; inter-examinadores foram encontradas diferenças significantes em todas as propriedades estéticas (brilho superficial, manchamento marginal, estabilidade de cor e translucidez e forma anatômica) e funcionais (fratura do material e retenção e adaptação marginal) observadas. A associação entre a imagem digital e o exame clínico pode ser uma ferramenta promissora para detecção de falhas precoces em restaurações de resina composta, necessitando de mais estudos que investiguem o método digital.
Title in English
Digital dentistry: study of the agreement between clinical and photographic assessments on composite resin restorations
Keywords in English
Clinical research; Composite resin; Digital dentistry; Operative dentistry; Photography
Abstract in English
The present study aimed to evaluate the agreement levels between clinical and digital photographic assessments on the performance of posterior composite resin restorations (Class I and Class II). The clinical assessments were made by two examiners (C1 and C2) calibrated through e-calib with the Fédération Dentaire Internationale (FDI) criteria considering esthetic, functional and biological properties. In each moment of clinical assessment, standard digital photographs of each restoration were obtained. Two digital examiners (D1 and D2), equally calibrated and using the same criteria, evaluated all the images obtained in the clinical assessment. The data were analyzed with the calculation of Cohen Kappa coefficient, Kruskal-Wallis non-parametric test and Dunn's multiple shared test, with significance of 5%. Intra (same method) and inter (different methods) comparisons were realized. The results showed that agreement levels varied from "Perfect" to "Fair". There was a significant difference (p < 0.05) intra-examiners; between C1 and C2 to the marginal staining parameter; between D1 and D2 in the parameters surface luster, colour match and translucency, esthetic anatomical form and fracture of material and retention; inter-examiners was noticed significant difference in all the esthetic (surface luster, colour match and translucency, marginal staining, esthetic anatomical form) and functional properties (fracture of material and retention and marginal adaptation) observed. The association between the digital image to the clinical exam may be a promising tool associated with the clinical method to detect early failures in composite resin restorations, requiring further studies investigating the digital method.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2018-09-13
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.