• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.58.2019.tde-04102022-174756
Documento
Autor
Nombre completo
Gabriela Ayres de Souza
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2019
Director
Tribunal
Muglia, Valdir Antonio (Presidente)
Ferracioli, Renata Cristina Silveira Rodrigues
Mazaro, José Vitor Quinelli
Rubo, Jose Henrique
Título en portugués
Influência de pilares protéticos sólidos para implantes Cone Morse instalados em diferentes profundidades ósseas na distribuição de tensões: análise por elementos finitos
Palabras clave en portugués
Conexão Cone Morse
Elementos finitos
Implantes dentários
Pilares protéticos
Resumen en portugués
A distribuição das forças mastigatórias dentro de limites fisiológicos para que a resposta tecidual não seja adversa é essencial. A seleção e o adequado posicionamento dos implantes dentários e componentes protéticos e o conhecimento da distribuição de tensões podem ajudar a evitar sobrecargas mecânicas, evitar falhas e garantir o sucesso das reabilitações com implantes dentários. O objetivo do estudo consistiu na avaliação da distribuição de tensões através de diferentes pilares protéticos sólidos conectados à implantes de conexão cônica instalados em diferentes profundidades ósseas por meio do método de elementos finitos. Foram confeccionados 4 modelos tridimensionais através do software Rhinoceros contendo: segmento ósseo mandibular posterior, implante (3,5x9,5 mm), pilar protético e coroa protética com infraestrutura em zircônia e recobrimento estético em cerâmica. Os itens de variação foram: diâmetro da base de assentamento protético do pilar (a:3,3 ou b:4,5 mm), altura do transmucoso (1,5 ou 3,0 mm) e a profundidade de instalação do implante (equicristal ou 1,5 mm subcristal). As situações analisadas foram: A-Equi - pilar a e implante equicristal; B-Equi - pilar b e implante equicristal; A-Sub - pilar a e implante subcristal e B-Sub - pilar b e implante subcristal. Foram inseridas as propriedades mecânicas dos materiais e simuladas cargas axiais e oblíquas no sentido línguo-vestibular (30º) de 365 N distribuídas em 8 pontos oclusais. As Tensões Equivalentes de von Mises (TEvM) foram avaliadas nos conjuntos implante/pilar e as Tensões Máximas (TMaP) e Mínimas Principais (TMiP) (MPa) em osso circunjacente, por meio do software HyperView. Os resultados mostram elevados níveis de tensões em todos os modelos submetidos à cargas oblíquas. As TMaP foram maiores nos modelos subcristais e as TMiP foram maiores nos modelos equicristais. O aumento do diâmetro de base de assentamento protética favorece a distribuição de tensões em coroa protética. O aumento da altura de transmucoso gera maiores tensões em região de junção pilar-implante quando submetidos à cargas axiais e menores tensões quando submetidos à cargas axiais. Através dos resultados do estudo foi possível concluir que a colocação de implantes subcristais geram menores tensões em crista óssea e que uma reabilitação com implantes dentários deve ser planejada de maneira que cargas oblíquas sejam minimizadas.
Título en inglés
Influence of solid abutments for implants with morse taper connection installed at different bone depths on the stress distribution: a finite elemento analysis
Palabras clave en inglés
Abutments
Dental implants
Finite element analysis
Morse taper connection
Resumen en inglés
The masticatory forces distribution within physiological limits so that the tissue response is not adverse is essential. Selection and proper positioning of dental implants and prosthetic components and knowledge of stress distribution can help prevent mechanical overloads, prevent failures, and ensure successful dental implant rehabilitation. The aim of the study was to evaluate the stress distribution through different solid prosthetic abutments connected to the conical connection implants installed at different bone depths by the finite element method. Four models were made using Rhinoceros software containing: posterior mandibular bone segment, implant (3.5x9.5 mm), prosthetic abutment and prosthetic crown with zirconia infrastructure and aesthetic ceramic coating. The variation items were: abutment prosthetic base (a: 3,3 or b: 4,5 mm), transmucosal height (1.5 or 3.0 mm) and implant installation depth (equicrestal or 1.5 mm subcrestal). The analyzed situations were: A-Equi-abutment a and equicrestal implant; B-Equi - b-abutment and equicrestal implant; A-sub-abutment and subcrestal implant and B-Sub-abutment b and subcrestal implant. The mechanical properties of the materials and simulated axial and oblique loads (30º) of 365 N distributed in 8 occlusal points were simulated. The von Mises Equivalent Stress (TEvM) were evaluated in the implant-abutment assemblies and the Maximal Stresses (TMaP) and Minimal Principal Stresses (TMi) (MPa) in the surrounding bone, using HyperView software. The results show high stress levels in all models submitted to oblique loads. The TMaPs were higher in the subcrestals models and the TMiPs were higher in the equicrestals models. The increase of the prosthetic base diameter favors the stress distribution in a prosthetic crown. The increase of the transmucosal height generates greater stress in area of obutment-implant junction when submitted to the oblique loads and smaller stress when submitted to the axial loads. Through the results of the study, it was possible to conclude that the subcristal placement implants generate lower bone crest stress and that a rehabilitation with dental implants should be planned in such a way that oblique loads are minimized.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2022-10-05
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.