Disertación de Maestría
DOI
https://doi.org/10.11606/D.58.2018.tde-04092017-082854
Documento
Autor
Nombre completo
Bruna Santos Honório Tonin
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2017
Director
Tribunal
Mattos, Maria da Gloria Chiarello de (Presidente)
Bernardes, Sérgio Rocha
Matsumoto, Wilson
Shimano, Antonio Carlos
Título en portugués
Influência do material e técnica de obtenção da infraestrutura na distribuição de tensão de próteses parciais fixas com cantilever
Palabras clave en portugués
Fotoelasticidade; Implantes dentários; Ligas dentárias; Prótese parcial fixa; Zirconia
Resumen en portugués
A passividade da prótese parcial fixa (PPF) sobre implante e a distribuição de tensões ao osso pela infraestrutura, contribuem não só com a osseointegração como também para a sua manutenção. A análise de tensões por fotoelasticidade permite visualizar as magnitudes de tensões e deformações em um modelo confeccionado em resina fotoelástica que possui padrão de concentração e distribuição de tensões semelhantes ao tecido ósseo. Assim, este estudo teve como objetivos comparar a distribuição de tensões de PPFs associadas à cantilever com diferentes materiais de infraestrutura (Co-Cr e Zircônia [Zr]) e métodos de obtenção (CAD/CAM e fundição convencional [monobloco, soldagem a laser e soldagem com TIG]), quando submetidos a diferentes carregamentos oclusais (puntiforme e oclusal distribuído). A partir de um modelo mestre, foram confeccionados 3 modelos fotoelásticos simulando extremidade livre mandibular,com o dente 44 em resina e 2 implantes substituindo os dentes 45 e 46. Os grupos deste estudo incluíram PPFs com infraestruturas obtidas por meio de fundição convencional em monobloco (G1), seccionadas e soldadas a laser (G2) e com TIG (G3) e obtidas por meio do sistema CAD/CAM em Co-Cr (G4) e Zr (G5). As PPFs foram parafusadas sobre os mini pilares e submetidas a carregamento oclusal puntiforme e distribuído (150 N) para avaliação qualitativa das franjas e quantitativa em seis diferentes pontos: apical (P1) e distal (P2) do dente 44, apical (P3) e distal (P4) do implante substituindo o dente 45, apical (P5) e distal (P6) do implante substituindo o dente 46. A análise fotoelástica mostrou maior concentração de tensões na PPF com infraestrutura em monobloco (G1) e menor concentração nas próteses obtidas pelo método CAD/CAM (G4 e G5). Quando submetidos ao carregamento oclusal distribuído, a PPF com infraestrutura em Zr (G5) apresentou um aumento considerável na concentração de tensões, seguida por monobloco (G1) e as que foram soldadas a laser (G2) e TIG (G3). No carregamento pontual sobre o cantilever, a infraestrutura em Co-Cr soldada a TIG (G3) mostrou a maior concentração de tensões. Dentro das limitações deste estudo, concluiu-se que PPFs com infraestruturas obtidas por meio do sistema CAD/CAM foram associadas com menor concentração de tensões e que a secção de infraestruturas metálicas para posterior soldagem pode também ser uma alternativa viável, de acordo com a distribuição de tensões peri-implantes.
Título en inglés
Influence of material and infrastructure obtaining techniques on the stress distribution of cantilever fixed partial dentures
Palabras clave en inglés
Dental alloys; Dental implants; Fixed partial denture; Photoelasticity; Zirconia
Resumen en inglés
The passivity of fixed partial denture (FPD) on implant and the stress distribution to the bone by the infrastructure, contribute not only to osseointegration but also to its maintenance. The stress analysis by photoelasticity allows visualizing the stresses and deformations magnitudes in a model fabricated in photoelastic resin that has a concentration pattern and stress distribution similar to the bone tissue. The aim of this study was to compare the stress distribution of cantilever FDPs with different infrastructure materials (Co-Cr and Zirconia [Zr]) and methods of manufacture (CAD/CAM and conventional casting [one piece, laser welding and welding with TIG]), when submitted to different occlusal loads (punctiform and distributed occlusal). From a master model, 3 photoelastic models were fabricated to simulate the mandibular free end, with the tooth 44 in resin and 2 implants replacing the teeth 45 and 46. The groups of this study included FPDs with infrastructures obtained by conventional casting in one piece (G1), sectioned and laser welded (G2) and TIG (G3) and obtained by the CAD/CAM system in Co-Cr (G4) and Zr (G5). The FDPs were screwed onto the abutments and subjected to punctate and distributed occlusal loading (150 N) for qualitative evaluation of the fringes and quantitative at six different points: apical (P1) and distal (P2) of the tooth 44, apical (P3) and distal (P4) of the implant replacing the tooth 45, apical (P5) and distal (P6) of the implant replacing the tooth 46. The photoelastic analysis showed a higher concentration of stresses in the FPD with one piece infrastructure (G1) and a lower concentration in the prosthesis obtained by CAD/CAM method (G4 and G5). When submitted to distributed occlusal loading, the FPD with Zr infrastructure (G5) showed a considerable increase in stress concentration, followed by one piece (G1) and those that were laser (G2) and TIG (G3) welded. In the cantilever load, the TIG welded Co-Cr infrastructure (G3) showed the highest stress concentration. Within the limitations of this study, it was concluded that FPDs with infrastructures obtained by the CAD/CAM system were associated with lower stress concentrations and that the section of metal infrastructures for later welding may also be a viable alternative, according to the peri-implant stress distribution.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2018-08-29
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.