• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.58.2019.tde-01102019-091315
Documento
Autor
Nombre completo
Wendel Teixeira
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2019
Director
Tribunal
Pedrazzi, Vinicius (Presidente)
Corrêa, Ivo Carlos
Mollo Junior, Francisco de Assis
Nascimento, Cássio do
Título en portugués
Avaliação in vitro da infiltração bacteriana na interface implante/componente protético após aplicação de gel contendo metronidazol, em conexões do tipo Cone Morse
Palabras clave en portugués
Contagem de colônia bacteriana
DNA-DNA checkerboard
Implantes dentários
Microbiologia
Prótese dentária fixada por implante
Resumen en portugués
O grau de adaptação na interface implante/componente protético demonstra a precisão na fabricação de um determinado sistema de implante. Quando uma pobre adaptação está presente, esta permite a infiltração de micro-organismos através da interface e a colonização dos espaços internos dos implantes, levando ao surgimento de reações inflamatórias dos tecidos peri-implantares e um possível insucesso clínico do tratamento. O objetivo deste trabalho foi avaliar, in vitro, a microinfiltração através da interface implante/componente protético, do meio externo para o interior dos implantes, pelo método de hibridização DNA-DNA Checkerboard. Foram utilizados 36 conjuntos de implantes Cone Morse/Mini-pilares, divididos em 3 grupos: Grupo A, onde foram avaliados sem a utilização do gel, que foi nosso grupo controle, Grupo B, onde foram avaliados após a utilização do gel inerte, e Grupo C, onde foram avaliados após a utilização do gel contendo metronidazol. Todos esses conjuntos implantes/componentes foram imersos em tubos de ensaio contendo saliva humana, e os resultados foram analisados através de análise estatística. A análise estatística foi realizada pelos testes Wald-Type e ANOVA Type Statistics. Quando comparamos a contagem de micro-organismos entre os 3 grupos avaliados verificamos que os valores se apresentam em ordem crescente. Diferenças estatisticamente significantes foram observadas entre os grupos Controle e Gel Inerte (p<0,001), e entre os grupos Controle e Gel contendo Metronidazol (p<0,001). Já quando a comparação é feita entre os grupos Gel Inerte e Gel contendo Metronidazol, não houve diferença estatisticamente significante (p>0,05). Concluímos que o gel antimicrobiano contendo metronidazol não foi eficaz na prevenção da ocorrência de infiltração de micro-organismos através da interface implante/componente protético, no sistema Cone Morse.
Título en inglés
In vitro evaluation of bacterial leakage at the implant/abutment interface after application of gel containing metronidazole in Cone-Morse connections type
Palabras clave en inglés
Dental implants
DNA-DNA checkerboard
Implant-supported dental prosthesis
Microbial colony count
Microbiology
Resumen en inglés
The degree of adaptation at the interface implant/abutment demonstrates the precision in the manufacture of a certain implant system. When a poor adaptation is present, it allows the infiltration of microorganisms through the interface and the colonization of the internal spaces of the implants, leading to the appearance of inflammatory reactions of the peri-implant tissues and a possible clinical failure of the treatment. The objective of this study was to evaluate in vitro the microleakage through the implant/ abutment interface, from the external environment to the interior of the implants, by the DNA-DNA Checkerboard hybridization method. Thirty-six sets of Cone Morse/Mini-pillar implants were used, divided into three groups: Group A, where they were evaluated without the use of the gel, which was our control group, Group B, where they were evaluated after inert gel, and Group C, where they were evaluated after the use of the metronidazole gel. All 3 implants/components sets were immersed in test tubes containing human saliva, and the results were analyzed by statistical analysis (Wald-Type and ANOVA Type Statistics). When we compare the count of microorganisms among the 3 evaluated groups we verified that the values are presented in ascending order. Statistically significant differences were observed between the Control and Inert Gel groups (p<0.001), and between the Control and Gel groups containing Metronidazole (p<0.001). When the comparison is made between the Gel Inert and Gel groups containing Metronidazole, there was no statistically significant difference (p>0.05). We concluded that the antimicrobial gel containing metronidazole was not effective in preventing the occurrence of infiltration of microorganisms through the implant/prosthetic interface, in the Cone Morse system.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2022-10-05
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.