• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.54.1992.tde-21072009-172318
Documento
Autor
Nombre completo
Dante Luis Chinaglia
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 1992
Director
Tribunal
Hessel, Roberto (Presidente)
Yoshida, Makoto
Zimmerman, Robert Lee
Título en portugués
O deslocamento do segundo ponto de cruzamento na curva de emissão eletrônica de polímeros com a dose de irradiação absorvida e suas implicações.
Palabras clave en portugués
Acelerador de elétrons
Curva de emissão
Emissão eletrônica
Teflon FEP
Resumen en portugués
Amostras de Teflón® FEP e Mylar C foram submetidas a um bombardeio eletrônico por longos períodos a fim de se verificar a existência de uma possível corrente de condução na fase final de um carregamento por feixe eletrônico. Em vez disso, descobriu-se que a energia associada ao segundo ponto de cruzamento da curva de emissão eletrônica do material bombardeado varia lentamente com o tempo de exposição à irradiação. Por outro lado foram descobertos também fortes indícios de que o centróide de carga sofre um deslocamento enquanto a amostra está sendo irradiada. A componente da corrente através da amostra, associada a qualquer um desses efeitos se superpõe à corrente de condução (se existir) e acaba tornando inviável a sua observação, enquanto um ou ambos os efeitos persistirem. Na realidade não é só a energia do segundo ponto de cruzamento que varia; toda a curva de emissão característica do material, que é fundamental para se entender os processos e carga e descarga de amostras, sofre modificação com a irradiação prolongada. Além disto, dois novos métodos para se carregar uma amostra de polímero estão sendo propostos. Um deles permite carregar uma amostra positivamente, por etapas, a tensões mais elevadas que o método convencional. O outro possibilita carregar negativamente uma amostra, lançando mão do mecanismo de auto-regulação para interrupção do processo de carga, o que só havia sido feito até o momento para um carregamento positivo. Um novo método para se descarregar uma amostra usando o próprio feixe eletrônico também é apresentado.
Título en inglés
The second cross over in the electronic emission curve shift with the absorbed radiation dose and its implication.
Palabras clave en inglés
Electron beam
Electronic emission
Emission curve
Teflon FEP
Resumen en inglés
Teflon® FEP and Mylar C samples were submitted to an electron beam during long periods of time in order to examine the possible existence of conduction current in the final stages of the charging process. It was found that the energy associated with the second crossover point in the electronic emission curve of the irradiated material varied slightly with the time of irradiation. On the other hand, strong evidence emerged that the charge centroid is shifted while the sample is being irradiated. The component of the current through the sample which is associated with any of these effects is superimposed to the conduction current (if present), hampering the identification of a conduction current. In fact, it is not only the energy of the second crossover point that varies, for the whole emission curve is modified upon prolonged irradiation. This emission curve is fundamental for understanding the charging and discharging processes in the samples. In addition, two new methods for charging a sample are being proposed. The first allows one to charge the sample positively to surface potentials that are higher than those obtained in the conventional method. The other method permits the sample to be charged negatively using the auto-regulation mechanism for interrupting the charging process; this had previously been done only for charging samples positively. A new method for discharging a sample using the electron beam is also presented.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2009-08-14
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.