Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.54.1984.tde-19052014-154254
Document
Auteur
Nom complet
Edson dos Santos Moreira
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 1984
Directeur
Jury
Slaets, Jan Frans Willem (Président)
Craievich, Aldo Felix
Linhares, Odelar Leite
Titre en portugais
Desenvolvimento de um analisador de altura de pulsos
Mots-clés en portugais
Instrumentação eletrônica
Microprocessador
Processamento digital de dados
Visualização de dados
Resumé en portugais
Neste trabalho descrevemos o desenvolvimento de um analisador de altura de pulsos. Este aparelho é essencial no estudo de sinais oriundos de sensores que detectam fenômenos físicos e codificam as informações na amplitude dos pulsos que fornecem na saída. O sistema compõe-se de um módulo de entrada de sinais conectado a um módulo de controle baseado no microprocessador 8085ª capaz de memorizar pulsos com até 1 uS de largura em 256 canais com resolução melhor que 20mV. Um módulo de comunicação dotado de interface serial é usado para transferência de dados para outros dispositivos através do protocolo RS232c. O módulo de operação e monitoração munido de teclado hexadecimal e saída analógica possibilita a visualização das curvas coletadas num monitor XY. A arquitetura do aparelho e os programas desenvolvidos para este sistema de baixo custo foram otimizados de forma a produzir um tempo morto típico de aproximadamente 100 uS. Como aplicação ele foi utilizado para levantamento de curvas no Laboratório de espelhamento de raios-x a baixo ângulo deste Departamento. O desempenho do aparelho foi testado através de comparações entre seus dados e os obtidos através de um similar, um PHA Northern modelo NS633, e conclui-se pela sua eficiência
Titre en anglais
The development of pulse height analyzer
Mots-clés en anglais
Data visuallization
Digital data processing
Electronic instrumentation
Microprocessor
Resumé en anglais
This work describes the development of a Pulse height analyzer. This equipment is essential to analyze data coming from detectors producing information codified in pulse amplitudes. The system developed consist of a Signal input module connected to a controller module based on a 8085A microprocessor capable to memorize pulses up to 1 us in 256 channels with a resolution better than 20mV. A Communication module with a serial interface is used for data transfer to a host computer using RS232c protocol. The monitoring and operation module consist of a hexadecimal Keyboard, a 6 digit 7-segment display and a XY monitor. The hardware and the software designed for this low cost system were optimized to obtain a typical dead time of approximately 100 uS. As application, this device was used to acquire curves at the Small Angle x-ray scattering laboratory in this Department. The apparatus performance was tested by comparing its data with a Northern Pulge height analyzer model NS633 output, with favorable results
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2014-05-20
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.