Nom complet
Rolando Fonseca Fernandes
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 1993
Directeur
Jury
Zimmerman, Robert Lee (Président)
Faria, Roberto Mendonça
Lejbman, Iuda Dawid Goldman Vel
Robilotta, Cecil Chow
Tannus, Alberto
Titre en portugais
Espectros de energia de feixe de elétrons terapêuticos : correlação entre parâmetros físicos e qualidade
Mots-clés en portugais
Não disponível
Resumé en portugais
Apresentamos uma análise e medidas dos espectros de energia dos feixes de elétrons terapêuticos, relacionando-a com a qualidade destes feixes. Parâmetros clínicos e físicos, importantes nos planejamentos radioterápicos e dosimetria das radiações, são analisados detalhadamente a partir de suas definições e as suas dependências com a largura do espectro. As medidas e estudos foram efetuadas com dois acelerados lineares clínicos de modelos diferentes: Mevatron 74 (UNICAMP SP) e Mevatron 12 (HC/FMRP/Ribeirão Preto SP) produzindo feixes de energias nominais variando de 5 a 12 MeV para o primeiro e, 3 a 11 MeV para o segundo. Verificamos que os valores previstos pela teoria semi-empírica para os parâmetros clínicos diferem daqueles medidos. Essas diferenças são importantes quando enfocadas sob a visão do desenho dos aceleradores e os resultados clínicos desejados
Titre en anglais
Not available
Mots-clés en anglais
Not available
Resumé en anglais
A new approach was described for clinical and physical parameters used in radiotherapy planning and dosimetry, studying their dependencies on spectral widths. Two different models of clinical linear accelerators were used-Mevatron 74 (UNICAMP/SP) and Mevatron 12 (HC/FMRP/Ribeirão Preto). Mevatron 74 produces beams with nominal energies from 5 up to 12 MeV and Mevatron 12 from 3 up to 11 MeV. It was verified that the values of cilinical parameters expected from a semi-empirical theory differ from that obtained experimentally. Such differences are relevant from the point of view of the design of electron accelerators, as wellas, of the target clinical results
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
RolandoFernandesD.pdf (6.22 Mbytes)
Date de Publication
2015-04-10
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.