Espectrômetro para EXAFS dispersivo com focalização sagital
Mots-clés en portugais
Não disponível
Resumé en portugais
Um novo espectrômetro para estudo de EXAFS em laboratórios, com tubos convencionais de raios-X, é apresentado. Este equipamento faz uso de um monocromador curvo para focalização sagital e usa a divergência na outra direção para fazer a dispersão em energia, permitindo que todos os pontos do espectro sejam coletados simultaneamente. O desempenho do espectrômetro para EXAFS foi avaliado com monocromadores planos e curvos. Aspectos como resolução em energia, redução no tempo de aquisição dos dados experimentais e calibração de energia, foram abordados, mostrando que monocromadores com raios de curvatura tão baixos quanto 60mm apresentam praticamente a mesma resolução em energia que os planos. Nos testes foram utilizadas amostras de Cobre e filmes como detectores unidimensionais
Titre en anglais
Not available
Mots-clés en anglais
Not available
Resumé en anglais
A new dispersive EXAFS spectrometer, for use with conventional laboratory x-ray sources, is presented. The equipment uses curved silicon monochromators for simultaneous focusing and dispersion of the available radiation, so that the whole spectrum is collected at one time. The performance of the spectrometer was studied with both curved and plane monochromators with respect to energy resolution, collection time reduction and energy calibration. The results show that there is practically no resolution deterioration, with respect to the plane monochromators, for radios of curvature as low as 60mm. For these tests x-ray films were used as linear detectors, which can be replaced by other low parallax unidimensional detectors, such as CCd type
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-03-20
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.