• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.54.1974.tde-09062014-102423
Document
Auteur
Nom complet
Jorge Feres Kfuri
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 1974
Directeur
Titre en portugais
Sobre a preparação de um sistema para medida do efeito eletro-ótico em cristais e resultados obtidos, para centro 'F' em alguns halogenetos alcalinos
Mots-clés en portugais
Centro F
Efeito eletro-ótico
Halogeneto alcalino
Resumé en portugais
A montagem de um sistema que permite a detecção de modulação no coeficiente de absorção ótica, devido ao campo elétrico aplicado, foi concluída. A máxima sensibilidade atingida foi de Δ K / K = 1,5 x 10-6 com resolução em comprimento de onda de 3 nm. O efeito Stark de 2ª ordem, na freqüência dupla da do campo elétrico aplicado foi medido para o centro F em KCl e KBr e comparado com provisões teóricas. Os valores obtidos para o KCl coincidem com os de Chiarotti, o que confirma o bom funcionamento do sistema, e diferem dos valores calculados teoricamente. Essa diferença é atribuída à correção do campo local. Os valores obtidos experimentalmente para a variação relativa do coeficiente de absorção foram: para KCl: ΔK / K = 2,93 x 10-5 (78° K) para KBr: ΔK / K = 2,85 x 10-5 (78° K)
Titre en anglais
About the preparation of a system for measuring the electro-optic effect in crystals and obtained results for F-center in some alkali halides
Mots-clés en anglais
Alkali halides
Electro-optic effect
F-center
Resumé en anglais
The assembly of a system which allows the detection of modulation in the coefficient of optical absorption, due to the applied electrical field, was completed. The maximum sensitivity achieve was Δ K / K = 1,5 x 10-6, in wave length, of 3 nm. The Stark effect of second order, in the frequency twice as that of the applied electrical field was measured for the center F in KCl and KBr and compared with theoretical previsions. The values obtained for KCl coincide with those of Chiarotti's, which confirms the good functioning of the system, and differ from the values calculated theoretically. This difference in ascribed to the correction of the local field. for KCl: ΔK / K = 2,93 x 10-5 (78° K) for KBr: ΔK / K = 2,85 x 10-5 (78° K).
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
JorgeFeresKfuriM.pdf (2.05 Mbytes)
Date de Publication
2014-08-18
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.