• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.5.2020.tde-31102020-192621
Documento
Autor
Nombre completo
Leandro Dias dos Santos
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2020
Director
Tribunal
Greve, Julia Maria D Andrea (Presidente)
Silva, Ronaldo Aparecido da
Carvalho, Celso Ricardo Fernandes de
Pompeu, José Eduardo
Título en portugués
Avaliação dos movimentos do tornozelo e da resposta eletromiográfia dos músculos tibial anterior e fibulares em plataforma de inversão súbita
Palabras clave en portugués
Adulto jovem
Atletas
Eletromiografia
Entorses e distensões
Futebol
Jovens
Plataforma súbita
Tornozelo
Resumen en portugués
A entorse do tornozelo é muito frequente na prática de atividades esportivas, podendo levar à instabilidade articular com consequências clínicas e de desempenho. A plataforma de inversão súbita do tornozelo, associada à eletromiografia tem sido usada para estudar o mecanismo de entorse do tornozelo. Objetivo: testar uma plataforma estática que simule o movimento de entorse do tornozelo (inversão súbita), associado à resposta eletromiográfica dos músculos fibulares e tibial anterior de jogadores de futebol. Métodos: a plataforma foi desenvolvida para realizar o movimento súbito da entorse dissociado em três eixos: inversão, rotação medial e flexão plantar. Também foi criado um programa de computador para leitura da latência, velocidade angular e tempo para atingir a amplitude máxima dos três eixos de movimentos e dos sinais eletromiográficos dos músculos fibulares e tibiais, sincronizados aos movimentos da plataforma. Foram avaliados 30 jogadores de futebol, sem entorse de tornozelo, na plataforma súbita. Cada atleta fez 10 testes, iniciados de forma aleatória. sendo cinco em cada perna. Resultados: Entre os testes, não houve diferença estatística das velocidades angulares, tempo de latência e tempo para atingir a amplitude máxima do movimento da flexão plantar e rotação medial. Durante o transcorrer dos testes, houve aumento da velocidade angular da inversão. Não houve diferença no tempo de latência e limiar de contração dos músculos tibial anterior e fibulares na comparação entre os lados dominante e não dominante. Conclusão: A plataforma estática súbita foi confiável para avaliar os movimentos executados pelo tornozelo durante a entorse, não havendo diferença no comportamento mecânico e eletromiográfico avaliados em 10 tentativas
Título en inglés
Evaluation of ankle movements and electromyographic response of the anterior tibial and fibular muscles on sudden inversion platform
Palabras clave en inglés
Ankle
Athletes
Electromyography
Soccer
Sprains and strains
Sudden platform
Young adult
Young people
Resumen en inglés
Ankle sprain is very frequent in the practice of sports activities and can lead to joint instability with clinical and performance consequence. The platform of sudden ankle inversion associated with electromyography has been used to study the mechanism of ankle sprain. Objective: test a static platform that simulates ankle sprain movement (sudden inversion), associated with the electromyographic response of fibular and tibial muscles from soccer players. Methods: the platform was developed to perform the sudden movement of the decoupled sprain in three axes: inversion, medial rotation and plantar flexion, with a computer program for reading latency, angular velocity and time to achieve maximum amplitude of the three axes of motion and also of the synchronized electromyographic signals of the fibular and tibial muscles. Thirty football players were evaluated, without ankle sprain, on the sudden platform. Each athlete did 10 tests, five of them on each leg. Results: Among the tests, there was no statistical difference in the angular velocities, latency and time to achieve the maximum range of movement of the plantar flexion and medial rotation. During the tests there was an increase in the angular speed of the inversion. There was no difference in latency time and contraction threshold of the anterior tibial and fibular muscles in the comparison between the dominant and non-dominant sides. Conclusion: The sudden static platform was reliable to evaluate the movements performed by the ankle during sprain, with no difference in mechanical and electromyographic behavior evaluated in 10 attempts
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2021-01-19
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.