• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.5.2008.tde-28052008-141554
Document
Auteur
Nom complet
Beatriz Mangueira Saraiva
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2008
Directeur
Jury
Vieira, Joaquim Edson (Président)
Capelozzi, Vera Luiza
Galvão, Clóvis Eduardo Santos
Heitor, Maria Luisa Zocal Paro
Negri, Elnara Márcia
Titre en portugais
Medidas de óxido nítrico no ar exalado de pacientes com história prévia de broncoespasmo no período intra-operatório
Mots-clés en portugais
Anestesia
Asma
Escarro/citologia
Espasmo brônquio
Óxido nítrico
Resumé en portugais
INTRODUÇÃO: Pacientes com vias aéres hiperresponsivas têm uma resposta exarcebada das vias aéreas a vários estímulos. Nestes pacientes, a simples intubação é a causa mais freqüente do broncoespasmo, levando a complicações no peri-operatório. O óxido nítrico está envolvido na regulação da função fisiológica bem como em doenças das vias aéreas e nos últimos anos seu papel vem sendo constantemente estudado na modulação da broncoconstrição. OBJETIVO: Estudar a possibilidade da medida de óxido nítrico exalado (NOex) ser um marcador de episódios de broncoespasmo no intra-operatório. MÉTODOS: 146.358 fichas anestésicas foram analisadas no período de 1999/2004. Ocorreram registros de broncoespasmos em 863 pacientes neste período. Destas, nove sujeitos foram identificados como não asmáticos (grupo broncoespasmo), 12 sujeitos foram diagnosticados como asmáticos (grupo asma) e 10 indivíduos sem história prévia de doença foram selecionados aleatoriamente como grupo controle. Todos os sujeitos foram submetidos à medida de óxido nítrico exalado (partes/bilhão), espirometria e coleta de escarro induzido com salina hipertônica. Os dados foram comparados utilizando ANOVA seguido do teste de Tukey e Kruskal-Wallis seguido do teste de Dunn's. RESULTADOS: Os grupos broncoespasmo e controle apresentaram espirometria normal, com medidas estatísticamente diferentes do grupo asma (p <0,05). As porcentagens de eosinófilos (mediana) no escarro induzido foram maiores no grupo asma [2,5 (0,4-6,8)], menores no grupo broncoespasmo [0,5 (0-1,3), e grupo controle [0,0 (0)]. A medida de óxido nítrico exalado foi maior no grupo dos asmáticos [81,5 (57,6-86,8)] em relação aos controles [18,7 (16,0-24,7)] (p=0,001). Não houve diferença entre grupos broncoespasmo e asma, ambos significantemente diferentes do grupo controle (p <0,05). CONCLUSÃO: Pacientes não asmáticos que apresentaram broncoespasmo no intra-operatório durante a anestesia e manipulação da traquéia, possuem níveis de óxido nítrico no ar expirado exalado elevado.
Titre en anglais
Exhaled nitric oxide measure from patients with previous history of intraoperative bronchospasm.
Mots-clés en anglais
Anesthesia
Asthma
Bronchial spasm
Nitric oxide
Sputum/cytology
Resumé en anglais
INTRODUCTION: Airways of patients with bronchial hyperreactivity are characterized by exaggerated bronchoconstriction in response to a variety of stimuli. Henceforth, bronchospasm may occur during induction of anaesthesia. Nitric Oxide is part of either physiologic or pathophysiologic airway regulation and its role has been investigated as a bronchoconstrictior modulator. OBJECTIVE: to address the possibility of exhaled nitric oxide measurement (NOex) as a marker of intraoperative bronchospasm. METHODS: 146.358 anesthesia registered forms were revised (period: 1999/2004). Bronchospasm occurrence appeared registered in 863. From those, nine were identified as non-asthmatics patients (Bronchospasm group). Also, 12 asthmatics constituted one additional group (Asthma group) and 10 subjects with no previous airway disease or symptoms were randomly selected as control group. All subjects were submitted to exhaled nitric oxide measurements (parts/billion), spirometry and induced sputum. The data were compared by ANOVA followed by the Tukey test and Kruskal- Wallis followed by Dunn's test. RESULTS: Both bronchospasm and control groups had normal lung function test, different from asthma group (p <0.05). The percentage of eosinophils (median) in induced sputum was higher for asthma [2.5 (0.4-6.8)] lower for bronchospasm [0.5 (0-1.3)] and control group [0.0 (0)]. Exhaled Nitric Oxide was higher for asthmatic patients [81.5 (57.6-86.8)], compared to control group [18.7 (16.0-24.7)] (p=0.001). There was no difference between bronchospasm and asthma groups both different from control (p <0.05). CONCLUSION: non-asthmatics patients with intraoperative bronchospasm detected during anesthesia after airway manipulation showed higher nitric oxide expired levels.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2008-06-24
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.