• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.5.2008.tde-25032009-102004
Document
Auteur
Nom complet
Alexandre Luque
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2008
Directeur
Jury
Seguro, Antonio Carlos (Président)
Crescentini, Milena Carlos Vidotto
Lucato, Jeanette Janaina Jaber
Titre en portugais
Efeitos da estratégia da ventilação mecânica na função renal de ratos normais
Mots-clés en portugais
Insuficiência renal aguda
Inulina
Ratos Wistar
Respiração artificial
Respiradores mecânicos
Taxa de filtração glomerular
Resumé en portugais
A ventilação mecânica (VM) tem sido recentemente associada ao desenvolvimento de falências orgânicas distais, como um fator contribuinte para a falência renal em pacientes com trauma e fator de risco para diálise e mortalidade em unidade de terapia intensiva (UTI). A estratégia ventilatória adotada pode influenciar estes efeitos. O objetivo do presente estudo é explorar a hipótese de que a estratégia de ventilação mecânica adotada pode influenciar na função renal. Delineamento: Randomizado, investigação animal experimental. Casuística: Ratos machos Wistar, anestesiados, paralisados e ventilados mecanicamente. Intervenção: Dois grupos com seis animais cada foram randomizados para receberem ventilação mecânica com volume corrente (VT) de 8ml/kg (VT8) ou 27ml/kg (VT27). Os parâmetros ajustados para grupo foram: a) VT 8ml/kg; Freqüência respiratória (FR) 60±7 rpm; pressão positiva expiratória final (PEEP) 3 cmH2O; Pico de pressão inspiratória (Pwap) 11.8±2 cmH2O; Pressão média de vias aéreas (Pawm) 6,33±0,22 e b) VT 27ml/kg; FR 30±5 rpm; PEEP 0 cmH2O; Pwap 22.7±4 cmH2O; Pawm 6,50±0,22. Mensurações e Resultados: O grupo VT27 apresentou redução significativa no clearance de inulina após 60 minutos de VM, indicando insuficiência renal aguda (0.6±0.05 ml/min/100g de peso corporal (PC)), e ainda mais acentuada após 90 minutos de VM (0.45±0.05 ml/min/100g de PC) comparada aos valores basais (0.95±0.07 ml/min/100g de PC), p<0.001. Nenhum dos dois grupos sofreram variações significativas em relação as variáveis hemodinâmicas e gasométricas. Conclusões: Observamos que o ritmo de filtração glomerular (RFG) mensurado pelo clearance de inulina é afetado pela estratégia de volume corrente empregado após 60 minutos de VM com 27ml/kg e caindo a valores mais baixo após 90 minutos de VM
Titre en anglais
Effects of mechanical ventilation strategy on renal function in normal rat model
Mots-clés en anglais
Acute renal failure
Artificial respiration
Glomerular filtration rate
Inulin
Mechanical ventilation
Wistar rats
Resumé en anglais
Mechanical Ventilation (MV) has been recently associated with development of distal organ failure and it is also a contributor factor for renal failure in trauma patients, and risk factor for dialysis and mortality rate in intensive care unit. The ventilatory strategy adopted might be influenced this effect. The aim of the present study was to explore the hypothesis that mechanical ventilatory strategy may contribute to decreased renal function. Design: Randomized animal laboratory investigation. Subjects: Anesthetized, paralyzed, and mechanically ventilated male Wistar rats. Interventions: Two groups of six rats each were randomized to receive tidal volume of either 8ml/kg or 27 ml/kg. Ventilation strategies for the two groups were as follows: a) 8ml/kg; frequency 60±7 beats/min; positive endexpiratory pressure, 3.0 cm H2O; and peak inspiratory airway pressure (Pawp), 11.8±2 cm H2O; and b) 27ml/kg; frequency 30±5 beats/min; positive end-expiratory pressure, 0 cm H2O; and peak inspiratory airway pressure (Pawp), 22.7±4 cm H2O; Both groups with the same mean airway pressure (Pawm), 6,33±0,21 and 6,5±0,22, respectively. Measurements and main Results: Rats ventilated with high tidal volume (27ml/kg) presented significantly decreased inulin clearance after 60 minutes of mechanical ventilation, indicating acute renal insufficiency (0.6±0.05 ml/min/BW) in comparison with basal values (0.95±0.07 ml/min/BW), p<0.001. We observed decreased in inulin clearance in rats that received high tidal volume, after 60 minutes of ventilation and even more significant at 90 minutes of ventilation (0.45±0.05 ml/min/BW) compared with basal values. No inulin clearance alteration was observed in control ventilation group (0.8±0.05 ml/min/BW basal vs. 0.72±0.03 ml/min/BW 120 min of MV). Conclusion: We concluded that GFR is affected by different strategies of mechanical ventilation, and after 60 minutes of high tidal volume (27ml/kg) ventilation the renal function marked decreased, getting worse after 90 minutes
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
alexandreluque.pdf (231.64 Kbytes)
Date de Publication
2009-04-06
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.