Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2007.tde-24102007-091222
Documento
Autor
Nombre completo
Harki Tanaka
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2007
Director
Tribunal
Ortega, Neli Regina de Siqueira (Presidente)
Carvalho, Carlos Roberto Ribeiro de
Lima, Raul Gonzalez
Tonelli, Pedro Aladar
Victorino, Josué Almeida
Título en portugués
Estudo da perfusão e ventilação pulmonar em imagens de tomografia de impedância elétrica através de modelagem fuzzy
Palabras clave en portugués
Impedância elétrica
Lógica fuzzy
Perfusão
Pneumotórax
Porcos
Tomografia
Ventilação pulmonar
Resumen en portugués
A Tomografia de Impedância Elétrica (TIE) é um método de imagem que está sendo desenvolvido para uso em medicina, especialmente na terapia intensiva. Visando uma melhoria da resolução anatômica das imagens de TIE, foi desenvolvido um modelo fuzzy que leva em consideração a alta resolução temporal e as informações funcionais, contidas nos sinais de perfusão pulmonar e ventilação pulmonar. Foram elaborados três modelos fuzzy: modelagem fuzzy do mapa cardíaco, do mapa de ventilação pulmonar e do mapa de perfusão pulmonar. Um mapa comparativo de ventilação e perfusão foi gerado através de uma segmentação das imagens, segundo notas de corte sobre os valores dos pixels. As imagens de perfusão fuzzy foram comparadas com as imagens de perfusão obtidas pelo método de injeção de uma solução hipertônica, considerada como padrão-ouro das imagens de perfusão. O desempenho do modelo foi avaliado através da análise das imagens de TIE obtidas em experimentos animais com treze porcos. Os animais foram submetidos a diferentes condições fisiológicas através de lesão pulmonar, recrutamento pulmonar e intubação seletiva. O modelo global foi capaz de identificar a região cardíaca e pulmonar em todos os porcos, independentemente das condições fisiológicas a que foram submetidos. Os resultados foram bastante expressivos tanto em termos qualitativos (a imagem obtida pelo modelo foi bastante similar a da tomografia computadorizada) quanto em termos quantitativos (a área média da curva ROC foi de 0,84). Os resultados do estudo poderão servir de base para o desenvolvimento de ferramentas clínicas, baseadas em TIE, para diagnósticos de algumas patologias e situações críticas, tais como distúrbio entre ventilação e perfusão, pneumotórax e tromboembolismo pulmonar.
Título en inglés
Study of the pulmonary perfusion and pulmonary ventilation with electrical impedance tomography images through fuzzy modeling
Palabras clave en inglés
Electrical impedance
Fuzzy logic
Lung perfusion
Pigs
Pneumothorax
Pulmonary ventilation
Tomography
Resumen en inglés
Electrical Impedance Tomography (EIT) is an image method that has been developed for use in medicine, specially in critical care medicine. Aiming at improving the anatomical resolution of EIT images a fuzzy model was developed based on EIT high temporal resolution and the functional information contained in the pulmonary perfusion and ventilation signals. Fuzzy models were elaborated for heart map modeling, ventilation and perfusion map modeling. Image segmentation was performed using a threshold method and a ventilation/perfusion map was generated. Fuzzy EIT perfusion map was compared with the hypertonic saline injection method, considered as the gold-standard for EIT perfusion image. The model performance was evaluated through analysis of EIT images obtained from animal experiment with thirteen pigs. The animals were submitted to different physiological conditions, such as ventilation induced lung injury, selective intubations and lung recruitment maneuver. The global model was able to identify both the cardiac and pulmonary regions in all animals. The results were expressive for both qualitative (the image obtained by the model was very similar to that of the CT-scan) and quantitative (the ROC curve area average was 0.84) analysis. These achievements could serve as the base to develop EIT diagnosis system for some critical diseases, such as ventilation to perfusion mismatch, pneumothorax and pulmonary thromboembolism.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
HarkiTanaka.pdf (7.31 Mbytes)
Fecha de Publicación
2007-11-07
 