Thèse de Doctorat
DOI
https://doi.org/10.11606/T.5.2005.tde-03102005-100300
Document
Auteur
Nom complet
Carolina Fu
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2005
Directeur
Jury
Carvalho, Carlos Roberto Ribeiro de (Président)
Okamoto, Valdelis Novis
Park, Marcelo
Tucci, Mauro Roberto
Vieira, Joaquim Edson
Titre en portugais
"Comparação entre dois geradores de fluxo e um ventilador específico para ventilação não invasiva no modo CPAP"
Mots-clés en portugais
MODELOS BIOLÓGICOS
PRESSÃO POSITIVA CONTÍNUA NAS VIAS AÉREAS/utilização
RESPIRAÇÃO ARTIFICIAL
Resumé en portugais
A pressão positiva contínua nas vias aéreas(CPAP) é a forma mais simples de ventilação não invasiva. O objetivo deste estudo é comparar o desempenho de dois modelos de gerador de fluxo com um ventilador projetado especificamente para ventilação não invasiva no modo CPAP, através de um modelo mecânico de pulmão e em voluntários sadios, em três diferentes alimentações de pressão e em CPAP de 5, 10 e 15 cm H2O. Conclui-se que os geradores de fluxo têm capacidade similar ao ventilador específico para manter o nível de CPAP, se ajustados para sua melhor pressão de alimentação, que foi ao redor de 100 L/min
Titre en anglais
Comparison of two flow generators and a noninvasive ventilator in deliver CPAP
Mots-clés en anglais
CONTINUOUS POSITIVE AIRWAY PRESSURE/utilization
MODELS BIOLOGICAL
RESPIRATION ARTIFICIAL
Resumé en anglais
Continuous positive airway pressure (CPAP) is the simplest form of noninvasive ventilation. Mechanical ventilators designed to invasive ventilation, ventilators specifically designed to noninvasive ventilation (NIV-Ventilator) and continuous flow generators can provide CPAP. The objectives of this study is compare the performance of two continuous flow generators with a ventilator designed to NIV to deliver continuous positive airway pressure (CPAP) and compare flow generators using different oxygen pressure supplies in lung model and healthy subjects, in CPAP of 5, 10 and 15 cm H2O. It was observed that flow generators had similar performance to noninvasive ventilator if they were adjust in their best output flow, that was around 100 L/min
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
CarolinaFu.pdf (616.52 Kbytes)
Date de Publication
2005-10-05
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.