• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.5.2008.tde-22032010-181957
Document
Auteur
Nom complet
Lilian Mika Horie
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2008
Directeur
Jury
Waitzberg, Dan Linetzky (Président)
Braghiroli Neto, Oddone
Moraes Filho, Joaquim Prado Pinto de
Titre en portugais
Desenvolvimento de equações preditivas de composição corporal para obesos graves: uso da bioimpedância elétrica
Mots-clés en portugais
Antropometria
Composição corporal
Impedância bioelétrica
Obesidade mórbida
Tecido adiposo
Resumé en portugais
INTRODUÇÃO: A obesidade grave dificulta fisicamente a avaliação da composição corporal. OBJETIVO: Desenvolver equações para estimativa de gordura corporal (GC) em obesos grau III. MÉTODOS: Adultos obesos graves tiveram a GC estimada por bioimpedância elétrica (BIA impedância de 5, 50, 100 e 200kHz) e por método de referência (pletismografia de deslocamento aéreo - PDA). Avaliaram-se os limites de concordância e seu coeficiente de correlação (CCC). Novas equações preditivas foram desenvolvidas por análise de regressão multivariada. RESULTADOS: A GC estimada por BIA e PDA foi similar para a população estudada (64,8 ± 15kg vs 65,6 ± 16kg, p>0,05). Ambas tiveram boa acurácia, precisão e CCC, porém a sua comparação teve amplos limites de concordância que variaram de -10,4 a 8,8kg. A equação residente de BIA aplicada em mulheres superestimou a GC (-1,3 kg; p<0,05) e em homens subestimou a GC (5,6 kg; p<0,05). Novas equações preditivas de GC foram criadas, para BIA de freqüência de 50kHz, Horie-Waitzberg & Barbosa-Silva1: GC1 (kg) = 23,25 + (0,13 × idade) + (1,00 × peso atual) + (0,09 × Resistência 50kHz) (0,80 × altura) e para BIA de frequência de 100kHz, Horie-Waitzberg & Barbosa-Silva2: GC2 (kg) = 23,97 + (0,10 × Impedância 100kHz) + (0,11 × idade) + (0,99 × peso atual) - (0,80 × altura). CONCLUSÕES: A equação residente no aparelho de BIA foi inadequada para estimar a GC em pacientes obesos grau III. As equações desenvolvidas especialmente para esta população forneceram estimativas de GC mais precisas (melhores limites de concordância, precisão, acurácia e CCC).
Titre en anglais
Development of body composition prediction equations for severely obese patients: the use of bioelectrical impedance
Mots-clés en anglais
Adipose tissue
Anthropometric
Bioelectrical impedance
Body composition
Severe obesity
Resumé en anglais
RATIONALE: Severe obesity limits physically the body composition assessment. AIM: To develop equations of body fat (BF) estimative in severe obesity. METHODS: Severely obese adults had BF estimated by bioelectrical impedance (BIA impedance of 5, 50, 100 and 200kHz) and reference method (air displacement plethysmography - ADP). The limits of agreement and of concordance correlation coefficient (CCC) of the data were evaluated. New predictive equations were developed by multivariate regression analysis. RESULTS: The BF estimations from BIA and ADP were similar for the studied population (64.8 ± 15kg vs 65.6 ± 16.4kg, p>0.05). Both had good accuracy, precision, and CCC, but their comparison had wide limit of agreement with range from -10.4 to 8.8kg. The home BIA equation overestimated BF in women (-1.3 kg, p<0,05) and underestimated BF in men (5.6 kg; p <0.05). BF new predictive equations were generated, for BIA with 50kHz frequency, Horie- Waitzberg & Barbosa-Silva1: BF1 (kg) = 23.25 + (0.13 × age) + (1.00 × current weight) + (0.09 × Resistance 50kHz) (0.80 × height) and for BIA with 100kHz frequency, Horie-Waitzberg & Barbosa-Silva2: BF2 (kg) = 23.97 + (0.10 × Impedance 100kHz) + (0.11 × age) + (0.99 × current weight) - (0.80 × height). CONCLUSIONS: The home equation on BIA was inadequate for estimating BF in severely obese patients. Equations developed especially for this population provides more accurate BF estimative (better limits of agreement accuracy, precision and CCC).
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
LilianMikaHorie.pdf (2.41 Mbytes)
Date de Publication
2010-05-28
 
AVERTISSEMENT: Le matériau se réfère à des documents provenant de cette thèse ou mémoire. Le contenu de ces documents est la responsabilité de l'auteur de la thèse ou mémoire.
  • HORIE, Lilian Mika, et al. New body fat prediction equations for severely obese patients. Clinical Nutrition [online], 2008, vol. 27, n. 3, p. 350-356. [cited 2011-11-12]. Available from : <http://www.clinicalnutritionjournal.com>
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.