• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.5.2007.tde-17022009-110641
Document
Auteur
Nom complet
Flávio Mendes de Andrade Neto
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2007
Directeur
Jury
Castro, Claudio Campi de (Président)
Caldas, José Guilherme Mendes Pereira
D'Ippolito, Giuseppe
Oliveira, Paulo Fabiani de
Wolosker, Nelson
Titre en portugais
Correlação entre a ressonância magnética e a ultra-sonografia com duplex scan colorido no diagnóstico da trombose venosa profunda dos membros inferiores
Mots-clés en portugais
Estudo comparativo
Imagem por ressonância magnética
Trombose venosa/diagnóstico
Ultra-sonografia Doppler em cores
Resumé en portugais
A trombose venosa profunda é uma doença que acomete o sistema venoso profundo, com formação de trombos dentro de uma veia e conseqüente reação inflamatória do vaso. O trombo pode determinar a obstrução parcial ou total do vaso. Ocorre em maior número nos membros inferiores e pelve. O quadro normalmente é agudo, mas pode se tornar crônico, com recidivas. Na maior parte dos casos, acomete os membros de forma unilateral. No presente estudo, foram utilizados dois métodos de diagnóstico por imagem na detecção de trombose venosa profunda, que foram a ultra-sonografia em escala de cinza (modo B) associada ao Duplex Scan colorido, e a ressonância magnética. Neste último, foi utilizado meio de contraste paramagnético (Gadolínio) através de administração venosa pediosa. Foram estudados um total de 26 pacientes, 47 membros inferiores e 141 segmentos corporais. A comparação entre os métodos de imagem foi feita por segmento venoso e por segmento corporal. O objetivo do estudo foi avaliar a concordância diagnóstica entre os métodos e a confiabilidade interobservadores nos exames de ressonância magnética, bem como avaliar a sensibilidade, especificidade e acurácia do Duplex Scan colorido em relação à ressonância magnética por segmentos venosos e corporais. Como conclusões do estudo, notamos que houve boa correlação entre a ultrasonografia e a ressonância magnética nos segmentos femorais comuns e superficiais, perfurantes da coxa, poplíteas, tibiais posteriores, fibulares e ilíacas externas. Também houve boa correlação entre os métodos na avaliação das coxas e pernas, e ausência de correlação significativa na pelve. Houve boa confiabilidade interobservadores nos exames de ressonância magnética por segmento venoso. A sensibilidade da ultrasonografia em relação à ressonância magnética foi excelente na pelve, coxas e pernas, sendo a especificidade e acurácia altas na coxa e perna, e baixas na pelve
Titre en anglais
Correlation between magnetic resonance and duplex color sonography in diagnosis of deep venous thrombosis in lower limbs
Mots-clés en anglais
Comparative study
Magnetic resonance imaging
Ultrasonography Doppler color
Venous thrombosis/diagnosis
Resumé en anglais
Deep venous thrombosis is a disease that occurs in deep venous system, with thrombi formation into a vein, and consequent vascular inflammatory reaction. This thrombus can determine partial or total vascular occlusion. It occurs mostly in the lower limbs and pelvis. Clinical presentation is usually acute, but may also be chronic with relapses. In most cases, limb disease is unilateral. In the present study, two different imaging techniques were used in the diagnosis of deep venous thrombosis: B-mode sonography with duplex color Doppler and magnetic resonance imaging with pedal vein administration of paramagnetic contrast media. Twenty-six patients, 47 lower extremities and 141 body segments were evaluated. Comparasion between techniques was made by vascular segments and body segments.The objectives of the study were to evaluate agreement in diagnosis between methods by vascular and body segments, interobserver reliability to read magnetic resonance exams, and sensibility, specificity and accuracy of duplex color sonography in relation to magnetic resonance imaging by vascular and body segments. In conclusion, there was a good correlation between ultrasound and magnetic resonance imaging at common and superficial femoral vein segments, thigh perfurants, calf veins, posterior tibial, fibular and external iliac veins. There was a good correlation between techniques in the evaluation of thighs and legs, but not in the pelvis. There was a good interobserver reliability in the evaluation of vascular segments by magnetic resonance imaging. The sensibility of duplex color sonography in relation to magnetic resonance imaging was excellent in pelvis, thighs and legs; specificity and accuracy were high in thighs and legs, and low in the pelvis
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
FlavioMendesANeto.pdf (2.29 Mbytes)
Date de Publication
2009-03-11
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.