Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2016.tde-12042016-151104
Documento
Autor
Nombre completo
Érika Yumi Watanabe
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2016
Director
Tribunal
Rodrigues, Laura Natal (Presidente)
Carvalho, Heloisa de Andrade
Ros, Renato Assenci
Weltman, Eduardo
Título en portugués
Comparação da técnica de radioterapia em arco modulada volumetricamente (VMAT) em relação à técnica de radioterapia de intensidade modulada (IMRT) para tumores de próstata e cabeça e pescoço
Palabras clave en portugués
Dose máxima permissível
Neoplasia da próstata
Neoplasias de cabeça e pescoço
Planejamento da radioterapia assistida por computador
Radioterapia
Radioterapia de intensidade modulada
Resumen en portugués
As técnicas de radioterapia vem sendo constantemente modificadas com a implementação de novas tecnologias visando aumentar a eficiência e diminuir a toxicidade dos tratamentos com radiação ionizante. Esse trabalho visa comparar as técnicas de radioterapia de intensidade modulada (IMRT) e a radioterapia em arco modulada volumetricamente (VMAT) em termos dosimétricos para o alvo e órgãos em risco além de avaliar a diferença do tempo de tratamento utilizando cada técnica. Para assegurar que os planejamentos seguiriam um padrão aceitável para ambas as técnicas, realizou-se primeiramente os planejamentos sugeridos pelo TG 119 da Associação Americana de Física Médica e compatibilidade dos resultados obtidos comparados com os dados da literatura. Tal comparação permitiu prosseguir para uma próxima etapa que consistiu da utilização de imagens de pacientes reais que foram submetidos a tratamentos de próstata e cabeça e pescoço, para a realização dos planejamentos utilizando as técnicas de IMRT e VMAT. A qualidade dosimétrica dos planejamentos utilizando ambas as técnicas foi avaliada em termos de conformidade e homogeneidade da dose no alvo e para os casos de pacientes com câncer de próstata, foram investigados os limites de dose em reto, bexiga e cabeça de fêmur, sendo avaliada a associação entre o volume de intersecção de reto e bexiga com o alvo. Para os   casos de pacientes com câncer de cabeça e pescoço, em termos dos limites de dose em medula, tronco cerebral e parótidas. Os planejamentos nos quais fez se uso da técnica de VMAT apresentaram valores semelhantes aos dos planos de IMRT. A análise dos tempos de tratamento para cada técnica avaliada mostrou que a VMAT reduz significativamente o tempo, até 67% para os casos de pacientes com câncer de próstata e até 36% para os casos de pacientes com câncer de cabeça e pescoço
Título en inglés
Volumetric modulated arc therapy (VMAT) and intensity modulated radiotherapy (IMRT) techniques comparison for prostate and head and neck tumors
Palabras clave en inglés
Head and neck neoplasms
Maximum acceptable dose
Prostatic neoplasms
Radiotherapy
Radiotherapy intensity-modulated
Radiotherapy planning computer-assisted
Resumen en inglés
The goal of this study was to compare the dosimetric aspects of volumetric-modulated arc therapy (VMAT) with those of intensity-modulated radiotherapy (IMRT) and to evaluate the delivery time and monitor unit differences between the two techniques, for applications in prostate and head and neck cancer treatment. First of all, to assure an acceptable pattern of treatment planning using both techniques, the TG119 of American Association of Medical Physics instructions were followed and the results of plans were compared to TG119 published data. The next step consisted of using real patients' images, whose underwent prostate radiotherapy or head and neck radiotherapy, to planning IMRT and VMAT. The dosimetric quality of plans using both techniques was evaluated in terms of target dose conformity and target dose homogeneity The dose constraints for rectum, bladder and femoral head were analyzed and the association between the rectum intersection volume and bladder intersection volume to the target volume were evaluated for the prostate cases. The dose constraints for spinal cord, brainstem and parotids were investigated for the head and neck cases. Best or similar values were obtained for the VMAT plans in relation to IMRT plans. The analysis of treatment time indicated a significant reduction using VMAT, until 67% to the prostate cases and 36% to the head and neck cases
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-04-12
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.