• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.5.2005.tde-15082005-115019
Document
Auteur
Nom complet
Jeanette Janaina Jaber Lucato
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2005
Directeur
Jury
Souza, Rogério de (Président)
Bogossian, Miguel
Carvalho, Carlos Roberto Ribeiro de
Isern, Maria Rita Montenegro
Tucci, Mauro Roberto
Titre en portugais
"Avaliação e comparação de diferentes tipos de trocadores de calor e umidade"
Mots-clés en portugais
AVALIAÇÃO
CALOR
EQUIPAMENTOS E PROVISÕES/efeitos adversos
ESTUDO COMPARATIVO
RESPIRAÇÃO ARTIFICIAL
UMIDADE
VENTILAÇÃO PULMONAR
Resumé en portugais
As tarefas de umidificação e aquecimento do ar inspirado podem ser realizadas por meio de trocadores de calor e umidade (HMEs - Heat and moisture exchangers). Os objetivos do nosso estudo são avaliar e comparar a capacidade de umidificação e aquecimento de oito diferentes tipos de HMEs em um modelo experimental com pulmão animal isolado e avaliar o impacto de cada um dos HMEs na ventilação alveolar em um modelo mecânico do sistema respiratório, com adição de CO2 a um fluxo de 0,65L/min. Os níveis de umidade e temperatura foram medidos durante a situação controle (nenhum HME) e com os diferentes HMEs quando volume corrente; freqüência respiratória e fluxo foram variados. A recuperação da umidade absoluta da expiração durante a próxima inspiração (% RAH) foi calculada. A % RAH aumentou com o uso do HME comparado ao controle. O volume corrente teve um significante efeito na % RAH, o que não ocorreu com alterações na frequência respiratória ou fluxo. O aumento do ETCO2 foi proporcional ao aumento do espaço morto dos HMEs. As alterações de fluxo ou a saturação dos HMEs não determinaram relevantes alterações no ETCO2
Titre en anglais
Evaluation and comparison among different heat and moisture exchangers
Mots-clés en anglais
COMPARATIVE STUDY
EQUIPMENT AND SUPPLIES/adverse effects
EVALUATION
HEAT
HUMIDITY
PULMONARY VENTILATION
RESPIRATION ARTIFICIAL
Resumé en anglais
When tracheal intubation is necessary during ventilatory support, the physiological mechanisms of heating and humidifying the inspired air are supressed, so it is vital the preconditioning of the inspired gases with the goal of offering water and heat contents similar to those normally provided by the upper airways. These tasks of humidification and heating can be accomplished through the use of heat and moisture exchangers (HMEs). Objectives: 1- Evaluate and compare the humidification and heating capacity of eight different types of HMEs in a respiratory system analog using preserved swine lung. 2- Evaluate the impact of each one of the tested HMEs over alveolar ventilation in a mevhanical model of the respiratory system
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2005-08-15
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.