• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2005.tde-15082005-115019
Documento
Autor
Nombre completo
Jeanette Janaina Jaber Lucato
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2005
Director
Tribunal
Souza, Rogério de (Presidente)
Bogossian, Miguel
Carvalho, Carlos Roberto Ribeiro de
Isern, Maria Rita Montenegro
Tucci, Mauro Roberto
Título en portugués
"Avaliação e comparação de diferentes tipos de trocadores de calor e umidade"
Palabras clave en portugués
AVALIAÇÃO
CALOR
EQUIPAMENTOS E PROVISÕES/efeitos adversos
ESTUDO COMPARATIVO
RESPIRAÇÃO ARTIFICIAL
UMIDADE
VENTILAÇÃO PULMONAR
Resumen en portugués
As tarefas de umidificação e aquecimento do ar inspirado podem ser realizadas por meio de trocadores de calor e umidade (HMEs - Heat and moisture exchangers). Os objetivos do nosso estudo são avaliar e comparar a capacidade de umidificação e aquecimento de oito diferentes tipos de HMEs em um modelo experimental com pulmão animal isolado e avaliar o impacto de cada um dos HMEs na ventilação alveolar em um modelo mecânico do sistema respiratório, com adição de CO2 a um fluxo de 0,65L/min. Os níveis de umidade e temperatura foram medidos durante a situação controle (nenhum HME) e com os diferentes HMEs quando volume corrente; freqüência respiratória e fluxo foram variados. A recuperação da umidade absoluta da expiração durante a próxima inspiração (% RAH) foi calculada. A % RAH aumentou com o uso do HME comparado ao controle. O volume corrente teve um significante efeito na % RAH, o que não ocorreu com alterações na frequência respiratória ou fluxo. O aumento do ETCO2 foi proporcional ao aumento do espaço morto dos HMEs. As alterações de fluxo ou a saturação dos HMEs não determinaram relevantes alterações no ETCO2
Título en inglés
Evaluation and comparison among different heat and moisture exchangers
Palabras clave en inglés
COMPARATIVE STUDY
EQUIPMENT AND SUPPLIES/adverse effects
EVALUATION
HEAT
HUMIDITY
PULMONARY VENTILATION
RESPIRATION ARTIFICIAL
Resumen en inglés
When tracheal intubation is necessary during ventilatory support, the physiological mechanisms of heating and humidifying the inspired air are supressed, so it is vital the preconditioning of the inspired gases with the goal of offering water and heat contents similar to those normally provided by the upper airways. These tasks of humidification and heating can be accomplished through the use of heat and moisture exchangers (HMEs). Objectives: 1- Evaluate and compare the humidification and heating capacity of eight different types of HMEs in a respiratory system analog using preserved swine lung. 2- Evaluate the impact of each one of the tested HMEs over alveolar ventilation in a mevhanical model of the respiratory system
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2005-08-15
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.