Titre en portugais
Estudo comparativo de estereopsia, aniseiconia e sintomas associados, em pacientes pseudofácicos bilaterais, com e sem anisometropia
Mots-clés en portugais
Aniseiconia
Anisometropia
Catarata
Facoemulsificação
Percepção de profundidade
Pseudofacia
Resumé en portugais
Objetivos: Comparar estereopsia, aniseiconia, e sintomas associados, em pacientes pseudofácicos bilaterais, com e sem anisometropia. Métodos: Foi realizado estudo clínico transversal em população de portadores de catarata senil, submetidos previamente à facoemulsificação com implante de LIO monofocal em ambos os olhos. Os pseudofácicos foram divididos em dois grupos: Grupo Controle (n=69) - diferença na refração pós-cirúrgica interocular pelo EE <1,00D e Grupo Anisometropia (n=42) - diferença na refração pós-cirúrgica interocular pelo EE 1,00D. A aniseiconia foi mensurada com o emprego do software Aniseikonia Inspector 3 e a estereopsia com o emprego do Randot estereoteste. A avaliação de dez sintomas associados com aniseiconia foi feita com a aplicação de um questionário. A análise dos dados foi feita por meios dos seguintes modelos estatísticos: análise univariada, multivariada e regressão múltipla. Resultados: A aniseiconia induzida pelas cirurgias de catarata foi de 0,64±1,41 % (Grupo Controle) e 0,62 ±1,76 % (Grupo anisometropia), diferença não significante (p=0,766). A estereopsia mensurada foi de 1,95±0,17 log10 segundos de arco (Grupo Controle) e de 2,12±0,22 log10 segundos de arco (Grupo Anisometropia), diferença significante (p<0,0001). A média dos sintomas associados com aniseiconia foi de 1,39±0,46 (Grupo Controle) e de 1,44±0,44 (Grupo Anisometropia), diferença não significante (p=0,461). A contribuição das variáveis independentes na predição da estereopsia no Grupo Anisometropia foi a seguinte: comprimento axial (18,06%); anisometropia (EE) (44,53%), aniseiconia (25,71%) e poder da LIO (11,71%). Conclusões: O estudo mostrou que estereopsia, aniseiconia e sintomas associados não representaram um problema substancial para o conforto visual de pacientes pseudofácicos bilaterais com anisometropia < 3D
Titre en anglais
A comparative study of stereopsis, aniseikonia, and symptoms associated, in patients with bilateral pseudophakia, with and without anisometropia
Mots-clés en anglais
Aniseikonia
Anisometropia
Cataract
Depth perception
Phacoemulsification
Pseudophakia
Resumé en anglais
Objectives: To compare stereopsis, aniseikonia, and symptoms associated, in bilateral pseudophakia, with and without anisometropia. Methods: A cross-sectional clinical study was conducted with a population of patients with senile cataracts, previously scheduled for phacoemulsification with unifocal IOL implant in both eyes. The pseudophakics were divided into two groups: Control Group (n=69) - difference interocular post-surgical refraction in spherical equivalent (SE) <1.00D and Anisometropia Group (n=42) - difference interocular post-surgical refraction in SE 1.00D. The aniseikonia was evaluated in the Aniseikonia Inspector 3 and stereopsis in the Randot stereotest. The evaluation of ten symptoms related to aniseikonia was done by applying a questionnaire. Statistical evaluation of data included models of univariate, multivariate, and regression analysis. Results: The aniseikonia induced by cataract surgery was 0.64±1.41% (Control Group) and 0.62 ±1.76% (Anisometropia Group), a non-significant difference (p=0.766). The stereoacuity measured was 1.95±0.17 units log10 arc seconds (Control Group) and 2.12±0.22 units log10 arc seconds (Anisometropia Group), a significant difference (p<0.0001). The mean of symptoms associated with aniseikonia were 1.39±0.46 (Control Group) and 1.44±0.44 (Anisometropia Group), a non-significant difference (p=0.461). The contribution of independent variables in predicting the stereopsis in the Anisometropia Group was the following: axial length difference (18.06%); SE difference (44.53%), aniseikonia (25.71%), and IOL power difference (11.71%). Conclusions: The study showed that stereopsis, aniseikonia, and associated symptoms did not stand for a substantial problem for visual comfort of bilateral pseudophakic patients with anisometropia < 3D
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
MarceloTannous.pdf (1.97 Mbytes)
Date de Publication
2022-07-20
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.