• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2022.tde-20072022-111121
Documento
Autor
Nombre completo
Marcelo Tannous
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2022
Director
Tribunal
Alves, Milton Ruiz (Presidente)
Andrade, Breno Barth Amaral de
Carricondo, Pedro Carlos
Damico, Francisco Max
Título en portugués
Estudo comparativo de estereopsia, aniseiconia e sintomas associados, em pacientes pseudofácicos bilaterais, com e sem anisometropia
Palabras clave en portugués
Aniseiconia
Anisometropia
Catarata
Facoemulsificação
Percepção de profundidade
Pseudofacia
Resumen en portugués
Objetivos: Comparar estereopsia, aniseiconia, e sintomas associados, em pacientes pseudofácicos bilaterais, com e sem anisometropia. Métodos: Foi realizado estudo clínico transversal em população de portadores de catarata senil, submetidos previamente à facoemulsificação com implante de LIO monofocal em ambos os olhos. Os pseudofácicos foram divididos em dois grupos: Grupo Controle (n=69) - diferença na refração pós-cirúrgica interocular pelo EE <1,00D e Grupo Anisometropia (n=42) - diferença na refração pós-cirúrgica interocular pelo EE 1,00D. A aniseiconia foi mensurada com o emprego do software Aniseikonia Inspector 3 e a estereopsia com o emprego do Randot estereoteste. A avaliação de dez sintomas associados com aniseiconia foi feita com a aplicação de um questionário. A análise dos dados foi feita por meios dos seguintes modelos estatísticos: análise univariada, multivariada e regressão múltipla. Resultados: A aniseiconia induzida pelas cirurgias de catarata foi de 0,64±1,41 % (Grupo Controle) e 0,62 ±1,76 % (Grupo anisometropia), diferença não significante (p=0,766). A estereopsia mensurada foi de 1,95±0,17 log10 segundos de arco (Grupo Controle) e de 2,12±0,22 log10 segundos de arco (Grupo Anisometropia), diferença significante (p<0,0001). A média dos sintomas associados com aniseiconia foi de 1,39±0,46 (Grupo Controle) e de 1,44±0,44 (Grupo Anisometropia), diferença não significante (p=0,461). A contribuição das variáveis independentes na predição da estereopsia no Grupo Anisometropia foi a seguinte: comprimento axial (18,06%); anisometropia (EE) (44,53%), aniseiconia (25,71%) e poder da LIO (11,71%). Conclusões: O estudo mostrou que estereopsia, aniseiconia e sintomas associados não representaram um problema substancial para o conforto visual de pacientes pseudofácicos bilaterais com anisometropia < 3D
Título en inglés
A comparative study of stereopsis, aniseikonia, and symptoms associated, in patients with bilateral pseudophakia, with and without anisometropia
Palabras clave en inglés
Aniseikonia
Anisometropia
Cataract
Depth perception
Phacoemulsification
Pseudophakia
Resumen en inglés
Objectives: To compare stereopsis, aniseikonia, and symptoms associated, in bilateral pseudophakia, with and without anisometropia. Methods: A cross-sectional clinical study was conducted with a population of patients with senile cataracts, previously scheduled for phacoemulsification with unifocal IOL implant in both eyes. The pseudophakics were divided into two groups: Control Group (n=69) - difference interocular post-surgical refraction in spherical equivalent (SE) <1.00D and Anisometropia Group (n=42) - difference interocular post-surgical refraction in SE 1.00D. The aniseikonia was evaluated in the Aniseikonia Inspector 3 and stereopsis in the Randot stereotest. The evaluation of ten symptoms related to aniseikonia was done by applying a questionnaire. Statistical evaluation of data included models of univariate, multivariate, and regression analysis. Results: The aniseikonia induced by cataract surgery was 0.64±1.41% (Control Group) and 0.62 ±1.76% (Anisometropia Group), a non-significant difference (p=0.766). The stereoacuity measured was 1.95±0.17 units log10 arc seconds (Control Group) and 2.12±0.22 units log10 arc seconds (Anisometropia Group), a significant difference (p<0.0001). The mean of symptoms associated with aniseikonia were 1.39±0.46 (Control Group) and 1.44±0.44 (Anisometropia Group), a non-significant difference (p=0.461). The contribution of independent variables in predicting the stereopsis in the Anisometropia Group was the following: axial length difference (18.06%); SE difference (44.53%), aniseikonia (25.71%), and IOL power difference (11.71%). Conclusions: The study showed that stereopsis, aniseikonia, and associated symptoms did not stand for a substantial problem for visual comfort of bilateral pseudophakic patients with anisometropia < 3D
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
MarceloTannous.pdf (1.97 Mbytes)
Fecha de Publicación
2022-07-20
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.