• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.5.2017.tde-22092017-151120
Document
Auteur
Nom complet
Valéria Regina de Cristo Alvares
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2017
Directeur
Jury
Elias, Rosilene Motta (Président)
Miorin, Luiz Antonio
Pereira, Benedito Jorge
Silva, Giovanio Vieira da
Titre en portugais
Avaliação hemodinâmica e de extração de solutos comparando exercício físico e compressão pneumática durante hemodiálise
Mots-clés en portugais
Diálise renal
Dispositivos de compressão pneumática intermitente
Exercício
Extração líquido-líquido
Fósforo
Hemodinâmica
Resumé en portugais
Introdução: à despeito da evolução dos aspectos técnicos do tratamento dialítico ao longo das últimas décadas, hipotensão intradialítica (HID) continua a ocorrer em uma parcela significante das sessões. Esquemas alternativos de diálise, especificamente sessões prolongadas e/ou frequentes tem se mostrado benéficas e se associam a um melhor controle da pressão arterial e da anemia, maior remoção de fósforo, regressão da hipertrofia ventricular esquerda, melhor controle de hipervolemia e aumento da sobrevida dos pacientes. A adoção destes métodos mais intensivos, entretanto, não é unânime e a maior parte da população em diálise no mundo realiza hemodiálise (HD) convencional 3 x semana. A HD convencional está associada à HID e à remoção ineficaz de fosfato. Como as pernas são a principal fonte de fluido extracelular removido durante o HD, procurou-se reduzir a HID e aumentar a remoção de fosfato usando exercício com cicloergômetro e compressão pneumática, o que potencialmente proporcionariam maior retorno venoso dos membros inferiores, preservando o fluxo sanguíneo central e também fazendo com que mais fosfato pudesse chegar ao dialisador, facilitando sua eliminação. Métodos: este é um estudo com intervenção, cruzado, onde foram avaliados 21 pacientes, em 3 diferentes sessões de HD: controle, exercício com cicloergômetro durante os primeiros 60 minutos de HD e compressão pneumática durante os primeiros 60 minutos de HD. Os dados avaliados foram: distribuição de fluidos (através de bioimpedância), pressão arterial hora a hora durante a HD, parâmetros bioquímicos e de remoção de fosfato (através de quantificação direta do dialisado). HID foi definida como uma queda na pressão arterial média (PAM) >= 20 mmHg. Resultados: não houve diferença na taxa de ultrafiltração (p = 0,628), delta de peso (p = 0,415), delta de água corporal total, intracelular e extracelular entre controle, cicloergômetro e compressão pneumática (p = 0,209, p = 0,348 e p = 0,467, respectivamente). Comparando controle, cicloergômetro e compressão pneumática, o delta de PAM foi menos negativo durante a compressão pneumática [-4,7 (-17,2, 8,2), -4,7 (-20,5, -0,2) e -2,3 (-8,1,9,0) mmHg, respectivamente; p = 0,021]. HID ocorreu em 43%, 38% e 24% dos pacientes em controle, cicloergômetro e compressão pneumática, respectivamente (p = 0,014). A remoção de fosfato não aumentou com nenhuma intervenção (p = 0,486). A remoção mais elevada de fosfato foi dependente da ultrafiltração, fosfato sérico pré-diálise e PTH mais elevado. Conclusão: A compressão pneumática durante a primeira hora de diálise foi associada a menor HID, embora não tenha sido observado efeito nos parâmetros de distribuição de fluidos. Nenhuma das intervenções testadas, seja exercício ou compressão pneumática conseguiu aumentar a remoção de fosfato
Titre en anglais
Evaluation of Hemodynamic and solute removal, a comparison between exercise and pneumatic compression during hemodialysis
Mots-clés en anglais
Hemodynamics
Intermittent pneumatic compression devices, Exercise
Liquid-liquid extraction
Phosphorus
Renal dialysis
Resumé en anglais
Introduction: Despite the evolution of the technical aspects of dialysis over the last decades, intradialytic hypotension (DIH) continues to occur in a significant proportion of the sessions. Alternative dialysis schemes such as prolonged and / or more frequent sessions have been shown to be beneficial and are associated with better control of blood pressure and anemia, greater phosphorus removal, regression of left ventricular hypertrophy, better control of hypervolemia, and increased survival of patients. The adoption of these methods, however, is not unanimous and the majority of the dialysis population worldwide are on conventional hemodialysis (HD) 3x week. Conventional HD is associated with DIH and it is also ineffective to remove phosphate. Since the legs are the main source of extracellular fluid removed during HD, we sought to reduce DIH and increase phosphate removal by using cycling exercise and pneumatic compression, which would potentially provide greater venous return from the lower limbs, preserving blood flow, and also offering more phosphate to the dialyser, facilitating its elimination. Methods: We evaluated 21 patients in a randomized crossover fashion in which each patient underwent 3 different HD: control; cycling exercise during the first 60-min; and pneumatic compression during the first 60-min. Data obtained included bioelectrical impedance, hourly blood pressure measurement, biochemical parameters, and directly quantification of phosphate through the dialysate. DIH was defined as a drop in mean arterial pressure (MAP) >= 20 mmHg. Results: There was no difference in ultrafiltration rate (p=0.628), delta weight (p=0.415), delta of total, intracellular and extracellular body water among control, cycling and pneumatic compression (p=0.209, p=0.348 and p=0.467, respectively). Delta MAP was less changed by pneumatic compression when compared to control, cycling and pneumatic compression, respectively [-4.7 (-17.2, 8.2), -4.7 (-20.5, -0.2) and -2.3 (-8.1,9.0) mmHg; p=0.021]. DIH occurred in 43%, 38% and 24% of patients in control, cycling and pneumatic compression, respectively (p=0.014). Phosphate removal did not increase in any intervention (p=0.486). Higher phosphate removal was dependent on ultrafiltration, pre-dialysis serum phosphate and higher PTH. Conclusion: Pneumatic compression during the first hour of dialysis was associated with less DIH, albeit no effect on fluid parameters was observed. Neither exercise nor pneumatic compression increased phosphate removal
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-09-26
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.