Disertación de Maestría
DOI
https://doi.org/10.11606/D.5.2021.tde-09092021-142126
Documento
Autor
Nombre completo
Lucas de Jesus Pereira
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2020
Director
Tribunal
Abensur, Hugo (Presidente)
Alexandre, Cristianne da Silva
Elias, Rosilene Motta
Figueiredo, Ana Elizabeth Prado Lima
Título en portugués
Uso da solução de icodextrina para avaliar a capacidade de transporte peritoneal
Palabras clave en portugués
Diálise
Diálise peritoneal
Icodextrina
Peritônio
Teste de equilíbrio peritoneal
Ultrafiltração
Resumen en portugués
INTRODUÇÃO: O Teste de Equilíbrio Peritoneal (PET) é o padrão ouro para avaliar o transporte peritoneal. A aferição do volume drenado após 4 horas de permanência de uma solução de glicose a 4,25% permite avaliar, de maneira simplificada, a integridade da membrana peritoneal. OBJETIVO: desenvolver um método para avaliar o padrão de transporte peritoneal apenas com a aferição do volume drenado após 4 horas de permanência de uma solução de icodextrina a 7,5%. MÉTODOS: 35 pacientes em programa de diálise peritoneal foram submetidos a 03 procedimentos: PET, verificação do volume drenado após 4 horas de permanência com a solução de glicose a 4,25% e verificação do volume drenado após 4 horas de permanência com a solução de ICO. RESULTADOS: Os pacientes transportadores rápidos tiveram maior volume ultrafiltrado com o emprego da icodextrina. Houve correlação negativa entre o volume ultrafiltrado com icodextrina e a relação D4/D0 de glicose (R= -0.579 e p=0.002) e correlação positiva entre o volume ultrafiltrado com icodextrina e a relação D/Pcr (R=0.474 e p=0.002). A área abaixo da Curva ROC foi 0.867 (p<0.001) e 0.792 (p=0.004) respectivamente com PET de creatinina e glicose. Com a solução de glicose a 4,25% ela foi menor 0.738 e 0.710 (p=0.020 e p=0.041, respectivamente). O cut off de 141ml discriminou os pacientes médio-rápidos e rápidos transportadores dos pacientes médio-lentos e lentos transportadores. CONCLUSÃO: O volume drenado após 4 horas de permanência com ICO prevê melhor os padrões de transportes peritoneais em comparação com o volume drenado com solução contendo glicose a 4,25%
Título en inglés
Use of icodextrin solution to evaluate peritoneal transport capacity
Palabras clave en inglés
Dialysis
Icodextrin
Peritoneal dialysis
Peritoneal equilibration test
Peritoneum
Ultrafiltration
Resumen en inglés
BACKGROUND: The peritoneal equilibration test (PET) is the gold standard for evaluating peritoneal transport, and measurement of the drain volume after a 4-h dwell time with glucose 4.25% is a simple means of evaluating peritoneal membrane integrity. OBJECTIVE: to develop a method to evaluate the pattern of peritoneal transport only by measuring the drain volume after a 4-h dwell time with icodextrin 7.5%. METHODS: Patients in a peritoneal dialysis program (N = 35) underwent three procedures: a PET; determination of the drain volume after a 4-h dwell time with glucose 4.25%; and determination of the drain volume after a 4-h dwell time with icodextrin. RESULTS: Among the patients who were classified as high transporters, the ultrafiltration volume was greater after icodextrin use. The icodextrin ultrafiltration volume correlated negatively with the ratio between the 4-h and 0-h dialysate glucose concentrations (D4/D0 ratio, r = -0.579; p = 0.002), correlating positively with the dialysate-to-plasma ratio for creatinine (D/PCr ratio, r = 0.474; p = 0.002). For icodextrin, the area under the receiver operating characteristic curve was 0.867 and 0.792 for the D/PCr and D4/D0 ratios (p < 0.0001 and p = 0.004, respectively), compared with 0.738 and 0.710 for glucose 4.25% (p = 0.020 and p = 0.041, respectively). A cut-off volume of 141 mL discriminated high/high-average transporters from low/low-average transporters. CONCLUSIONS: The volume drained after icodextrin use better predicts peritoneal transport patterns than does that drained after the use of glucose 4.25%.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2021-09-09
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.