• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.5.2011.tde-27072011-174211
Document
Author
Full name
Patricia da Rocha Pennachiotti Pitarello
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2011
Supervisor
Committee
Ruano, Rodrigo (President)
Bittar, Roberto Eduardo
Nomura, Marcelo Luis
Title in Portuguese
Avaliação do colo uterino pela ultrassonografia transvaginal para predição do sucesso da indução do parto
Keywords in Portuguese
Colo uterino/ultrassonografia
Comprimento do colo do útero
Sucesso da indução do parto
Trabalho de parto induzido
Abstract in Portuguese
Objetivo: Correlacionar as variáveis ultrassonográficas do colo uterino ao sucesso da indução do parto e ao Índice de Bishop. Métodos: Estudo observacional prospectivo envolvendo 190 gestantes candidatas à indução do parto, que foram submetidas à ultrassonografia transvaginal para avaliação do comprimento do colo uterino, da distância da apresentação fetal ao OCE, dilatação cervical e identificação da imagem em funil no OCI, no período de fevereiro de 2008 a fevereiro de 2010. As pacientes foram categorizadas segundo o escore de Bishop em favoráveis e desfavoráveis à IP. Os seguintes desfechos foram analisados: probabilidade de sucesso da IP, parto vaginal em 24 horas e presença de fase ativa do parto. A análise estatística foi realizada usando testes qui-quadrado, teste t-Student e Mann- Whitney para as variáveis numèricas, além do cálculo das curvas ROCs para cada variável e cada desfecho. Através de regressão logística foram avaliados os preditores dos desfechos assim como determinadas equações de probabilidade dos eventos. Resultados: O sucesso da IP, o parto vaginal em 24 horas e a presença de fase ativa do parto foram observados em 133 (70%) 119 (62%) e 155 (82%) das gestantes, respectivamente. O comprimento do colo uterino, a distância da apresentação fetal ao OCE, a dilatação cervical e a presença da imagem em funil no OCI influenciaram o sucesso da IP, a presença de parto vaginal em 24 horas e a presença de fase ativa do parto, principalmente em gestantes com escore de Bishop desfavorável à IP. As variáveis ultrassonográficas apresentaram sensibilidade entre 63 e 71% e especificidade entre 63 e 82% e acurácia média de 70%. O escore de Bishop se correlacionou diretamente à dilatação cervical e inversamente ao comprimento do colo uterino e à distância da apresentação fetal ao OCE e foi preditor independente de todos os desfechos da indução do parto (p<0,001). Conclusão: O comprimento do colo uterino, a distância da apresentação fetal ao OCE, a dilatação cervical e presença da imagem em funil no OCI se relacionaram ao sucesso da IP, porém com baixo poder de predição
Title in English
Cervix evaluation by transvaginal ultrasound for success prediction on labor induction
Keywords in English
Cervical lenght
Cervix /ultrasound
Labor induced
Sucessful labor induction
Abstract in English
Objective: To correlate the ultrasonographic variables of cervix to the success on labor induction (LI) and Bishops Index. Methods: A prospective, observational study involving 190 pregnant women that were applicant for labor induction, submitted to transvaginal ultrasound to evaluate the cervixs length, fetal head-external os distance, cervical dilatation and identification of funnel image on internal os, during the period between February 2008 and February 2010. Patients were classified according to Bishops score as favorable and unfavorable to labor induction. The following conclusions were studied: success probability to LI, vaginal delivery in 24 hours and presence of labors active phase. Statistical analysis was performed using chi-square tests, t-Student and Mann-Whitney test for numerical variables, in addition to ROCs curves calculation for each variable and each conclusion. By logistic regression, the conclusion predictors were evaluated, as well as some determined equations from events probability. Results: The labor induction success, vaginal delivery in 24 hours, and presence of labors active phase were noticed on 133 (70%), 119 (62%) and 155 (82%) pregnant women, respectively. Cervixs length, fetal head-external os distance, cervical dilatation and identification of funnel image on internal os influenced the LI success, vaginal delivery at 24 hours and presence of labors active phase, especially on pregnant with Bishops score unfavorable to labor induction. Ultrasonographic variables had sensitivity between 63 and 71%, specificity between 63 and 82%, and 70% of average accuracy. Bishops score was directly correlated to cervical dilatation and inversely correlated to cervixs length and fetal head-external os distance and was a independent predictor to all conclusions of labor induction (p<0.001). Conclusion: The cervixs length, fetal head-external os distance, cervical dilatation and identification of funnel image were related to LI success but with low prediction potency
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2011-08-01
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.