• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.5.2014.tde-13082014-144551
Document
Auteur
Nom complet
Douglas Bandeira Fernandes
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2014
Directeur
Jury
Liao, Adolfo Wenjaw (Président)
Barini, Ricardo
Francisco, Rossana Pulcineli Vieira
Titre en portugais
Valores de referência para área de secção transversa do cordão e vasos umbilicais aferidos pela ultrassonografia em gestações gemelares dicoriônicas
Mots-clés en portugais
Artérias umbilicais/ultrassonografia
Cordão umbilical/ultrassonografia
Geleia de Wharton/ultrassonografia
Gravidez de gêmeos
Peso fetal
Ultrassonografia
Ultrassonografia pré-natal
Veias umbilicais/ultrassonografia
Resumé en portugais
OBJETIVO: Determinar os valores de referência, e examinar a correlação da área de secção transversa do cordão umbilical, e de seus componentes, com a idade gestacional (IG), em gestações gemelares. Examinar a correlação da área de secção transversa do cordão umbilical com o peso fetal estimado (PFE). MATERIAIS E MÉTODOS: Estudo prospectivo longitudinal envolvendo gestações gemelares dicoriônicas, não complicadas. Medidas ultrassonográficas das áreas de secção transversa do cordão umbilical (ASTCU), da veia (AVU) e artérias umbilicais (AAU), e da geleia de Wharton (AGW) foram obtidas em plano adjacente, próximo ao abdômen fetal, a cada três semanas. A correlação entre os parâmetros avaliados e a idade gestacional foi investigada por meio de modelo de regressão polinomial hierárquica, levando-se em consideração a variância segundo a idade gestacional, entre medidas obtidas em fetos da mesma gestação e, entre diferentes gestações. Para cada parâmetro estudado, foram calculados os valores correspondentes aos percentis 5, 10, 50, 90 e 95, para cada semana gestacional. RESULTADOS: Foram realizadas 334 avaliações ultrassonográficas em 44 gestações gemelares, entre 18 e 33 semanas (média: 3,8 ± 0,7 exames/gestação; intervalo médio entre exames: 3,3 ± 0,9 semanas). Os valores log-transformados de todos os parâmetros avaliados apresentaram correlação significativa (p<0,001) com a idade gestacional: Log(ASTCU) = - 2,287498 + 0,149298 x IG - 0,002302 x IG2, desvio-padrão DP = 0,113, R2 = 0,65; Log (AVU) = - 2,721487 + 0,119853 x IG - 0,001507 x IG2, DP=0,165, R2 = 0,58; Log (AAU) = - 4,223546 + 0,195454 x IG - 0,003080 x IG2, DP=0,163, R2 = 0,57; Log (AGW) = - 2,511648 + 0,157737 x IG - 0,002564 x IG2, DP=0,123, R2 = 0,55. A área de secção transversa do cordão umbilical apresentou correlação significativa com o peso fetal estimado (Log (ASTCU) = -1,602447 + 0,554502 x Log (PFE), R2 = 0,65, p < 0,001). CONCLUSÃO: Em gestações gemelares dicoriônicas, a área de secção transversa do cordão umbilical, e de seus componentes, mostram correlação positiva e significativa com a idade gestacional. A área de secção transversa do cordão umbilical também correlaciona-se significativamente com o peso fetal estimado
Titre en anglais
Reference values for cross-sectional area of the umbilical cord and vessels measured by ultrasound in dichorionic twin pregnancies
Mots-clés en anglais
Fetal weight
Pregnancy twin
Ultrasonography prenatal
Ultrassonography
Umbilical arteries/ultrasonography
Umbilical cord/ultrasonography
Umbilical veins/ultrasonography
Wharton jelly/ultrasonography
Resumé en anglais
OBJECTIVE: To determine reference values, and examine the correlation between the cross-sectional area of the umbilical cord, and its components, with gestational age (GA) in twin pregnancies. To examine the correlation between the cross-sectional area of the umbilical cord with the estimated fetal weight (EFW). MATERIALS AND METHODS: A prospective longitudinal study involving uncomplicated dichorionic twin pregnancies. Sonographic measurements of the cross-sectional areas of the umbilical cord (UCCSA), umbilical vein (UVA) and arteries (UAA) and Wharton's jelly (WGA) were obtained in a plane adjacent to the fetal abdomen, every three weeks. The correlation between these parameters and gestational age was examined with hierarchical polynomial regression analysis. This modeling took into account the variance according to gestational age, fetuses within the same pregnancy and changes across different pregnancies. For each parameter, 5th, 10th, 50th, 90th and 95th centiles were calculated for each gestational week. RESULTS: 334 ultrasound scans were performed in 44 twin pregnancies, between 18 and 33 weeks (mean: 3.8 ± 0.7 scans/pregnancy, mean interval between scans: 3.3 ± 0.9 weeks). All umbilical cord log-transformed values showed a significant correlation (p < 0.001) with gestational age: Log (UCCSA) = - 2.287498 + 0.149298 x GA - 0.002302 x IG2, SD = standard deviation 0.113, R2 = 0.65, Log (UVA) = - 2.721487 + 0.119853 x GA - 0.001507 x IG2, SD = 0.165, R2 = 0.58, Log (UAA) = - 4.223546 + IG x 0.195454 - 0.003080 x IG2, SD = 0.163, R2 = 0.57, Log (WGA) = - 2.511648 + 0.157737 x GA - 0.002564 x IG2 , SD = 0.123, R2 = 0.55. The cross-sectional area of the umbilical cord also correlated significantly with the estimated fetal weight (Log (UCCSA) = -1.602447 + 0.554502 x Log (EFW), R2 = 0.65, p < 0.001). CONCLUSION: In dichorionic twin pregnancies, the cross-sectional areas of the umbilical cord, and its components, show a positive and significant correlation with gestational age. The cross-sectional area of the umbilical cord also has correlates significantly with the estimated fetal weight
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2014-08-14
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.