• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.5.2016.tde-03022016-093418
Documento
Autor
Nombre completo
Karen Nogueira Chinoca Ziza
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2015
Director
Tribunal
Liao, Adolfo Wenjaw (Presidente)
Pereira, Juliana
Brizot, Maria de Lourdes
Chinen, Paulo Alexandre
Título en portugués
Determinação do genótipo RHD fetal no plasma materno: acurácia do teste semiautomatizado
Palabras clave en portugués
Diagnóstico pré-natal/métodos
DNA/análise
Sangue fetal
Sensibilidade e especificidade
Sistema do grupo sanguíneo Rh-Hr
Técnicas de genotipagem
Resumen en portugués
INTRODUÇÃO: A determinação do genótipo RHD fetal no plasma materno é um teste de diagnóstico pré-natal não invasivo oferecido a gestantes RhD negativo que apresentam potencial de sensibilização e/ou Doença Hemolítica Perinatal. Atualmente, este exame é realizado de rotina em diversos países, mas não no Brasil. A Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) oferece atendimento terciário a gestantes RhD negativo, com monitorização dos títulos de anticorpos irregulares, administração da imunoglobulina anti-D e/ou terapêutica fetal, quando necessários. OBJETIVO: Avaliar a acurácia do teste semiautomatizado para determinação do genótipo RHD fetal no plasma materno. METODOLOGIA: Foram coletadas prospectivamente amostras de sangue de 220 gestantes RhD negativo, com idade gestacional entre 8-28 semanas. O plasma foi obtido em no máximo 2 horas após a coleta, e uma alíquota de 1 mL foi submetida à extração de ácidos nucléicos no equipamento automatizado MagNA Pure Compact (Roche), empregando o kit Large Volume. O DNA extraído foi submetido a PCR em tempo real (Step One Plus - Applied Biosystems), usando o protocolo do grupo SAFE, que tem como alvos os éxons 5 e 7 do gene RHD. RESULTADOS: Ocorreu exclusão de 35 amostras devido a problemas pré-analíticos, aborto ou desconhecimento do fenótipo do recém-nascido. Entre as 185 amostras analisadas, 130 (70,2%) foram genotipadas como RHD+ e 55 (29,8%) RHD-. Os resultados obtidos foram comparados com a fenotipagem do cordão umbilical, e houve concordância completa (100%). Sete amostras exibiram amplificação exclusiva para o éxon 7. Essas amostras foram submetidas aos protocolos em PCR convencional, e PCR em tempo real específico para o pseudogene RHD. Ambos os ensaios apresentaram os mesmos resultados: cinco positivos e dois negativos. Nesses mesmos 7 casos, após extração da camada de leucócitos materna, os protocolos foram repetidos, e o resultado confirmou que cinco mães eram RHD. As duas amostras com resultado negativo foram submetidas ao protocolo Multiplex, envolvendo os éxons 3-9 do gene RHD, com resultados negativos, confirmando que as mães são verdadeiramente RHD- portanto o sinal do éxon 7 é provindo dos fetos que são D variantes. CONCLUSÃO: O método para a determinação do RHD fetal no plasma materno descrito demonstrou ser rápido, de fácil execução, alta precisão e reprodutível, além de indicar possíveis variantes RHD em nossa população
Título en inglés
Fetal RHD genotype determination in maternal plasma: Accuracy of a semi-automated test
Palabras clave en inglés
Fetal blood
Genotyping techniques
Prenatal diagnosis/methods
Rh-Hr blood group system, DNA/analysis
Sensitivity and specificity
Resumen en inglés
BACKGROUND: Fetal RHD genotype determination in maternal plasma is a noninvasive prenatal diagnostic test performed in RhD negative pregnant women at risk of alloimmunization and/or Hemolytic Disease of Fetus and Newborn. Currently, this test is routinely performed in many countries but not in Brazil. The Department of Obstetrics at Hospital das Clínicas, São Paulo University Medical School provides tertiary antenatal care for RhD negative pregnant women including anti-D immunoglobulin administration, antibody levels monitoring and intrauterine treatment if necessary. AIMS: To validate the accuracy of a semi-automated test for fetal RHD genotype determination in maternal plasma. METHODS: Two-hundred and twenty blood samples were prospectively collected between 8 and 28 weeks of gestational age. Plasma processing was performed within 2 hours after blood collection, and nucleic acids were extracted from 1mL aliquots with an automated extraction platform (MagNA Pure Compact Roche) and the Large Volume kit. RHD gene exons 5 and 7 were amplified with real-time PCR (Step One Plus - Applied Biosystems) using the SAFE group protocol. RESULTS: Thirty-five samples were excluded due to pre-analytical problems, miscarriage and missing follow-up. In the remaining 185 samples, 130 (70.2%) were genotyped as RhD+ and 55 (29.8%) RhD-. Comparison with umbilical cord blood group phenotype showed 100% concordance. Seven samples showed amplification for exon 7 only. These were further investigated with conventional and real-time PCR with an specific protocol for RHD? pseudogene: 5 were positive and 2, negative. In these 7 cases, maternal buffy-coat DNA analysis also confirmed that 5 women were RHD?. In the remaining 2 cases, a multiplex protocol directed at RHD gene exons 3-9 confirmed that both mothers were truly RhD negative so exon 7 signal comes from the fetuses, further found to harbor D variants. CONCLUSION: The present study demonstrates that fetal RHD determination in maternal plasma is a fast, easy-to-perform and reproducible technique with high accuracy in our population. Moreover, it helps in the identification of possible RHD variants in our population
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-02-04
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.