• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.5.2018.tde-07112018-111536
Document
Auteur
Nom complet
Maira de Robertis Azevedo
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2018
Directeur
Jury
Shu, Edson Bor-Seng (Président)
Belon, Alessandro Rodrigo
Paiva, Wellingson Silva
Pedroso, José Luiz
Titre en portugais
Avaliação ultrassonográfica do diâmetro da bainha do nervo óptico em modelo experimental usando diferentes medicações anestésicas
Mots-clés en portugais
Anestesia
Modelos animais
Nervo óptico
Neurocirurgia
Pressão intracraniana
Ultrassonografia
Resumé en portugais
Introdução: a pressão intracraniana pode ser monitorada por meio de vários métodos que podem ser invasivos ou não invasivos. A ultrassonografia do nervo óptico é uma técnica não invasiva que permite mensurar a bainha deste nervo e detectar possíveis variações no seu diâmetro. O nervo óptico faz parte do sistema nervoso central de maneira contígua e é envolvido por uma bainha. Sendo assim, elevações ou reduções da pressão intracraniana podem ser transpostas à bainha deste nervo com consequente variação do seu diâmetro. Essas variações podem ser observadas pela ultrassonografia. Objetivo: determinar, por meio da ultrassonografia, o diâmetro da bainha do nervo óptico normal e avaliar os possíveis efeitos das drogas neste diâmetro durante a indução anestésica em suínos hígidos com pressão intracraniana normal. Métodos: foram selecionados 118 suínos híbridos saudáveis (64 fêmeas) de aproximadamente 20 kg e faixa etária similar. Todos os suínos foram submetidos à anestesia geral e foram devidamente monitorados. Os animais foram divididos em três grupos conforme os medicamentos utilizados: Grupo A: utilizando medicamento pré-anestésico xilazina e quetamina; Grupo B: utilizando xilazina (X), quetamina (Q) mais Propofol (P), e Grupo C: anestesiados com xilazina, quetamina e tiopental [tionembutal (T)]. As coletas das medidas nos três grupos foram feitas pelo aparelho de ultrassom em triplicata de cada olho, com os animais em posição laterolateral. Resultados: não houve diferenças estatisticamente significantes entre sexo e peso. O Diâmetro médio da bainha do nervo óptico em ambos os lados de cada grupo foram de 0,394±0,048 cm (X/Q), 0,407±0,029 cm (X/Q/P) e 0,378±0,042 cm (X/Q/T). Considerando todos os grupos, o diâmetro da bainha do nervo óptico variou de 0,287 cm a 0,512 cm (média 0,302 ± 0,039 cm). Houve diferenças estatisticamente significativas entre os grupos P e T (P > T, p = 0,003). Não foram detectadas diferenças significativas quando outros grupos foram comparados entre si. Conclusão: o diâmetro médio da bainha do nervo óptico, considerando todos os grupos, foi 0,302 ± 0,039 cm (0,287 cm - 0,512 cm) e 0,344 cm ± 0,048 cm nos indivíduos sedados apenas com X/Q
Titre en anglais
Ultrasonographic evaluation of the optic nerve sheath diameter in an experimental model using different anesthetic medications
Mots-clés en anglais
Anesthesia
Intracranial pressure, Ultrasonography
Models animal
Neurosurgery
Optical nerve
Resumé en anglais
Introduction: the intracranial pressure can be monitored by various methods that may be invasive or non-invasive. Ultrasonography of the optic nerve is a technique non-invasive that allows measurement of the nerve sheath and detection of possible variations in its diameter noninvasively. The optic nerve is part of the central nervous system continuously and is surrounded by a sheath. Thus, with the increase or reduction of intracranial pressure, it can be transposed to the sheath of this nerve with consequent variation of its diameter. These variations can be observed through the ultrasound image. Objective: determine the normal optical nerve sheath diameter and to evaluate the possible effects of drugs on optical nerve sheath diameter during anesthetic induction in healthy pigs with normal intracranial pressure through ultrasound image. Methods:118 Healthy hybrid piglets from (64 female) the weighing approximately 20 kg each and of similar ages. All pigs underwent general anesthesia and were duly monitored. The animals were divided into three groups according to the medications used. Group A received preanesthetic xylazine and ketamine; Grupo B received xylazine, ketamine and propofol, and Grupo C received xylazine, ketamine, and thiopental (thionembutal). Measurements in the three groups were done by the ultrasound device in triplicate of each eye from the left and right sides. Results: There were no statistically significant differences between sex and weight. The mean optical nerve sheath sizes on both sides in each group were 0.394±0.048 cm (X/K), 0.407±0.029 cm (X/K/P) and 0.378±0.042 cm (X/K/T). Considering all the groups, the diameter of the optic nerve sheath varied from 0.287-0.512 cm (mean of 0.302±0.039 cm). There were statistically significant differences between the groups P and T (P > T, p=0.003). No statistically significant differences were detected when other groups were compared each other. Conclusion: The mean diameter of the optic nerve sheath considering all groups was 0.302±0.039 cm (0.287-0.512 cm) and 0.394±0.048 cm in the subjects only sedated with X/K
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2018-11-09
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.