• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tese de Doutorado
DOI
https://doi.org/10.11606/T.5.2004.tde-24102005-143648
Documento
Autor
Nome completo
Paulo de Tarso Jorge Medeiros
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2004
Orientador
Banca examinadora
Martinelli Filho, Martino (Presidente)
Dodinot, Bernard
Fernández, Edmundo Arteaga
Pimenta, João
Sarabanda, Alvaro Valentim Lima
Título em português
"Cardiomiopatia hipertrófica: importância dos eventos arrítmicos em pacientes com risco de morte súbita"
Palavras-chave em português
ARRITMIA/complicações
DESFIBRILADORES IMPLANTÁVEIS
FATORES DE RISCO
MARCA-PASSO ARTIFICIAL
MIOCARDIOPATIA HIPERTRÓFICA/epidemiologia
MORTE SÚBITA CARDÍACA/prevenção & controle
SEGUIMENTOS
Resumo em português
Vinte e seis pacientes com cardiomiopatia hipertrófica e fatores de risco de morte súbita, foram submetidos a implante de cardioversor-desfibrilador implantável de dupla-câmara, com seguimento médio de 19 meses. Observou-se quatro choques em arritmias letais, 4 pacientes apresentaram TVNS e 5 taquiarritmias supraventriculares. Ocorreu um óbito.Conclusões: Observamos: TPSV em 19,2%; TVNS em 15,4% e TVS/FV em 15,4%. Nenhuma variável clínica ou demográfica, discriminou o comportamento clínico ou funcional pós-implante de CDI; a recorrência de síncope pós implante de CDI, não se associou à presença de eventos arrítmicos e a hipertrofia maior que 30 mm se associou à choque precoce do CDI (p=0,003).
Título em inglês
Hypertrophic cardiomyopathy: sudden cardiac death in high risk patients and the role of arrhythmias
Palavras-chave em inglês
ARRYTHMIA/complications
CARDIOMYOPATHY HYPERTROPHIC/epidemiology
DEATH SUDDEN CARDIAC/prevention & control
DEFIBRILLATORS IMPLANTABLE
FOLLOW-UP STUDIES
PACEMAKER ARTIFICIAL
RISK FACTORS
Resumo em inglês
During 19 months of average follow-up period, we followed 26 patients with hypertrophic cardiomyopathy and high risk for sudden death, all treated by dual chamber implantable cardioverter-defibrillator. 4 patients had received appropriate ICD discharge, 4 patients with NSVT and 5 supraventricular arrhythmias. One death had occurred. Conclusions: we observed: supraventricular arrhythmias in 19,2%; NSVT in 15,4% and VT/VF in 15,4%. The clinical or demographic outcomes did not suggest any clinical or functional results after ICD implantation; syncope may occur after ICD implantation and no arrhythmias recordered by intracardiac electrograms and left-ventricular-wall thickness greater than 30 mm is associated with early ICD shocks (p=0,003).
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2005-10-25
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.