• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.5.2005.tde-05092005-115223
Documento
Autor
Nombre completo
Roberto Chaves Castro
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2005
Director
Tribunal
Grinberg, Max (Presidente)
Cardoso, Luiz Francisco
Costa, Eduardo Augusto da Silva
Sampaio, Roney Orismar
Spadaro, Joel
Título en portugués
"Circulação periférica em pacientes com insuficiência aórtica crônica e indicação de troca valvar"
Palabras clave en portugués
CIRCULAÇÃO SANGÜÍNEA
COMPLACÊNCIA
ENDOTÉLIO/fisiopatologia
IMPLANTE DE PRÓTESE
INSUFICIÊNCIA DA VALVA AÓRTICA/fisiopatologia
PRESSÃO ARTERIAL
SEGUIMENTOS
Resumen en portugués
Introdução: O recente aperfeiçoamento da ultra-sonografia permitiu a análise estrutural e funcional do vaso. Casuística e Métodos: 36 pacientes com insuficiência aórtica e indicação de troca valvar, divididos em grupos com pressão arterial diastólica (PAD) superior e inferior a 50mmHg, avaliados antes e seis meses após a cirurgia. A função arterial compreendeu a complacência, distensibilidade e a função endotelial pela dilatação fluxo-mediada e nitrato-mediada. Conclusão: A complacência e a distensibilidade foram maiores no grupo com menor PAD e diminuíram após a cirurgia. A disfunção endotelial foi presente em insuficiência aórtica crônica independente do nível da pressão arterial diastólica
Título en inglés
Peripheral circulation in patients with chronic aortic insufficiency and valve replacement indication
Palabras clave en inglés
AORTIC VALVE INSUFFICIENCY/physiopathology
BLOOD CIRCULATION
BLOOD PRESSURE
COMPLIANCE
ENDOTHELIUM/physiopathology
FOLLOW-UP STUDIES
PROTHESIS IMPLANTATION
Resumen en inglés
Introduction: The recent improvement of ultrasonography made possible a functional and structural analysis of the vessel. Methods: 36 patients with aortic insufficiency and valve replacement need, divided in 2 groups with diastolic blood pressure (DBP) above and below 50mmHg. Checked twice: before and 6 months after surgery. The arterial function comprised compliance, distensibility and endothelial function through flow-mediated dilatation and nitrate-mediated dilatation. Conclusion: The compliance and distensibility were higher in the group with lower DBP and decreased after surgery. Endothelial dysfunction was present in chronic aortic insufficiency no matter the level of DBP
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
RobertoChavesCastro.pdf (463.39 Kbytes)
Fecha de Publicación
2005-10-07
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.