• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.5.2023.tde-05022024-155106
Document
Author
Full name
Ítalo Bruno dos Santos Sousa
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2023
Supervisor
Committee
Scanavacca, Mauricio Ibrahim (President)
Chokr, Muhieddine Omar
Costa, Guilherme Drummond Fenelon
Sternick, Eduardo Back
Title in Portuguese
Eficácia e segurança da ablação por cateter de vias acessórias para-hissianas: estudo randomizado comparativo entre crioablação e radiofrequência
Keywords in Portuguese
Ablação por radiofrequência
Crioablação
Eletrofisiologia cardíaca
Feixe acessório atrioventricular
Síndrome de Wolff-Parkinson-White
Técnicas de ablação
Abstract in Portuguese
Fundamentação: A ablação percutânea permanece como estratégia de escolha para tratamento definitivo de vias acessórias de condução atrioventricular, contudo a depender da localização a taxa de sucesso e de complicações podem variar. As vias acessórias para-hissianas (VAPH) encontram-se perto do sistema nativo de condução, em particular proximidade ao feixe de His, e por isso há risco aqui de bloqueio atrioventricular total (BAVT) durante ablação. Existem atualmente duas modalidades de energia que podem ser utilizadas neste cenário, crioterapia e radiofrequência, porém até o momento não há estudos comparativos prospectivos e randomizados entre as duas modalidades. Objetivo: Avaliar o perfil de segurança e eficácia da ablação percutânea de VAPH, comparando os resultados obtidos com uso das duas modalidades de fonte de energia existentes na literatura: crioterapia (CRIO) e radiofrequência (RF). Métodos: estudo piloto prospectivo intervencionista, randomizado 1:1, não-cego, unicêntrico. Foram incluídos pacientes portadores de VAPH confirmados por estudo eletrofisiológico (EEF) com indicação de ablação conforme diretrizes vigentes. Resultados: Entre outubro/2018 e fevereiro/2020 foram randomizados 30 pacientes, 90% do sexo masculino e com idade média de 25 anos. A taxa de sucesso inicial foi igual entre os grupos RF e CRIO (93% vs. 87%, p=0,54), bem como taxa de recorrência (14% vs. 30%, p=0,3) e trauma mecânico da via (6% vs. 20%, p=0,28). Houve 2 casos de BAVT transitório no grupo CRIO, nos quais a amplitude do sinal do feixe de His era significativamente maior do que naqueles em que não houve a complicação (0,8 + 0,07mV vs. 0,35 + 0,17mV, p=0,004). A taxa de recorrência foi semelhante entre os grupos, bem como sobrevida livre de eventos em um ano de seguimento (Log-Rank p=0,286 para múltiplos procedimentos), com média de 1,2 procedimentos por paciente. Não houve surgimento de BAVT ou distúrbio de condução persistente em ambos os grupos. Acréscimo de monitor de eventos ao exame clínico munido de eletrocardiograma de repouso não identificou casos adicionais de recorrência. Conclusão: respeitando-se as limitações de tamanho da amostra e de incidência de eventos, a ablação percutânea de vias acessórias para-hissianas foi realizada com segurança e taxas de sucesso aceitáveis. Não foram identificados casos de BAVT persistente em ambos os grupos. O presente estudo gera a hipótese de equivalência entre as modalidades de energia, desde que empregadas em centro de expertise, e abre portas para ensaios de maior número amostral
Title in English
Efficacy and safety of parahisian accessory pathway ablation: randomized comparison between cryotherapy and radiofrequency energy sources
Keywords in English
Ablation techniques
Accessory atrioventricular bundle
Cardiac electrophysiology
Cryoablation
Radiofrequency ablation
Wolff-Parkinson-White syndrome
Abstract in English
Background: Percutaneous ablation remains the strategy of choice for definitive treatment of AV accessory pathways; however, success rate and complications may vary according to cardiac site. Parahisian accessory pathways (PHAP) are positioned near the native conduction system, and for this reason they pose a greater risk of total atrioventricular block (TAVB) during the procedure. There are currently two types of energy sources that can be used in this scenario, cryotherapy (CRYO) and radiofrequency (RF), but so far there are no randomized prospective comparative studies described in the literature. Objective: To evaluate the safety and efficacy profile of percutaneous PHAP ablation, comparing cryotherapy and radiofrequency (RF). Methods: prospective, non-blinded, single-center interventional randomized 1:1 pilot study. Patients included had PHAP confirmed by electrophysiological study (EPS) referred for ablation according to current guidelines were included. Results: 30 patients were randomized (90% male) between October/2018 and February/2020 with a mean age of 25 years. The initial success rate was the same between the RF and CRIO groups (93% vs. 87%, p=0.54), as well risk of recurrence (14% vs. 30%, p=0.3) and mechanical trauma of the pathway (6% vs. 20%, p=0.28). There were 2 cases of transient AVB in the CRYO group, in which the His bundle signal amplitude was significantly greater than in those without AVB (0.8 + 0.07mV vs. 0.35 + 0.17mV, p=0.004). The recurrence rate was similar between groups, as well as event-free survival after one-year follow-up (Log-Rank p=0.286 for multiple procedures), with a mean of 1.2 procedures per patient. There was no emergence of TAVB or persistent conduction disturbance in either group. The addition of an event monitor to the clinical examination with resting electrocardiogram did not identify additional cases of recurrence. Conclusion: with due limitations of sample size and incidence of events, percutaneous ablation of parahisian accessory pathways may be performed safely and with acceptable success rates. No occurrence of persistent TAVB was found in both groups. The present study generates the hypothesis that radiofrequency and cryotherapy may be equivalent regarding PHAP percutaneous ablation, as long as they are used in a center of expertise, and points toward a need for larger randomized multicenter trials
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2024-02-19
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.