• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.46.2014.tde-27072015-142504
Document
Auteur
Nom complet
Luiza Maria Ferreira Dantas
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2014
Directeur
Jury
Bertotti, Mauro (Président)
Pedrotti, Jairo Jose
Santos, Mauro Coelho dos
Serrano, Silvia Helena Pires
Tanaka, Auro Atsushi
Titre en portugais
Uso de eletrodos de cobre e eletrodos modificados como sensores eletroquímicos
Mots-clés en portugais
Glicerol
Métodos eletroanalíticos
Microeletrodos de cobre
Nanotubos de carbono
Paládio
Peróxido de hidrogênio
Resumé en portugais
Este trabalho foi dividido em quatro etapas, além da introdução. A primeira parte consiste no estudo comparativo do comportamento eletroquímico de eletrodos de cobre em soluções tampão fosfato 0,10 mol L-1 com valores de pH 4,5 e 7,8, e em solução de NaOH com valores de pH 13,0 e 14,0. Mostrou-se que as espécies formadas eletroquimicamente sobre a superfície do eletrodo são dependentes do valor de pH e do potencial aplicado. Os resultados experimentais obtidos estão de acordo com aqueles reportados na literatura. A segunda parte da tese corresponde ao desenvolvimento de um sensor eletroquímico fabricado com microeletrodos de cobre para a determinação de peróxido de hidrogênio (H2O2) em amostras comerciais de antissépticos bucais e clareadores dentais. Nas condições experimentais otimizadas (solução tampão fosfato 0,10 mol L-1 (pH 7,0) e potencial de redução de -0,20 V), microeletrodos de cobre foram utilizados para a determinação de H2O2 sem a necessidade de etapas de extração, obtendo-se faixa linear de 0,015 a 6,4 mmol L-1 e limite de detecção de 2,8 µmol L-1. O método proposto mostrou-se reprodutível e a presença de interferentes na matriz da amostra analisada não alterou a resposta do sensor para H2O2. Na terceira parte, a reação de eletro-oxidação de glicerol em superfícies de cobre em soluções de NaOH foi investigada utilizando a microscopia eletroquímica de varredura (SECM) no modo de geração pelo substrato de cobre / coleta no microeletrodo de platina (tip) (SG/TC). Os experimentos com a SECM mostraram a dependência da corrente com a distância entre o gerador e a tip, assim como a dependência com a concentração da solução de NaOH. Além disso, a corrente monitorada no microeletrodo diminuiu significativamente após a adição de glicerol. A atividade eletrocatalítica de eletrodos de cobre, no que diz respeito à oxidação de glicerol em meio alcalino, permitiu o desenvolvimento de um sensor amperométrico para a determinação de glicerol em amostra de biodiesel, com um intervalo linear de 0,05 a 1,33 mmol L-1 e limite de detecção de 20 µmol L-1. A metodologia proposta foi aplicada para a determinação do analito em uma amostra de biodiesel de mamona. A quarta parte descreve a síntese, caracterização eletroquímica e utilização de nanotubos de carbono de paredes múltiplas (NCPM) decorados com nanopartículas de paládio (Pd) para a modificação da superfície de eletrodo de carbono vítreo (CV) para a oxidação de metanol, etanol e glicerol em solução de KOH 1,0 mol L-1. Os resultados mostraram que o NCPM/Pd é um bom catalisador para a eletro-oxidação de álcoois em meio alcalino e que maior atividade eletrocatalítica foi obtida para o glicerol. Em condições otimizadas, experimentos amperométricos foram realizados para o desenvolvimento do método analítico para a determinação de glicerol em biodiesel, obtendo-se um intervalo linear de 0,06 a 24 mmol L-1 e limite de detecção 30 µmol L-1. Amostras de biodiesel foram analisadas com sucesso por meio de curvas de adição de padrão utilizando o eletrodo CV/NCPM/Pd.
Titre en anglais
Use of copper and modified electrodes as electrochemical sensors
Mots-clés en anglais
Carbon nanotube
Copper microelectrode
Electroanalytical methods
Glycerol
Hydrogen peroxide
Palladium
Resumé en anglais
This thesis is divided into four parts, apart from a general introduction. Part 1 is concerned with a critical comparison of the electrochemical behaviour of copper electrodes, in 0.10 mol L-1 phosphate buffer solution (pH 4.5 and 7.8), and in NaOH solution (pH 13.0 and 14.0). The electrochemical study showed that the species formed on the surface depends on both pH and the applied potential. The experimental results are in good agreement with those reported in the literature. A second goal of the thesis was the development of an electrochemical sensor for hydrogen peroxide (H2O2) determination in commercial oral antiseptic and dental whitening samples using copper microelectrodes. With optimized experimental conditions (working potential applied = -0.20 V in 0.10 mol L-1 phosphate buffer solution pH= 7.0), copper microelectrodes can be used to detect H2O2 without any previous extraction steps, in the range of 0.015 to 6.4 mmol L-1 with a lower detection limit of 2.8 µmol L-1. In addition, the electrode exhibited an excellent reproducibility and long-term stability as well as negligible interference from sorbitol, ethanol, glycerin and saccharin. In the third part, the electrooxidation reaction of glycerol at copper surfaces in NaOH solutions was investigated using Scanning Electrochemical Microscopy (SECM) in a copper substrate generation / platinum microelectrode (tip) collection mode (SG/TC). The results showed the dependence of the current measured at the tip with respect to the distance between generator and the tip, as well as on the concentration of the NaOH solution. Other studies led to the conclusion that the current measured at the tip decreased significantly after addition of glycerol in the solution. The electrocatalytic activity of copper electrodes for the oxidation of glycerol in alkaline medium allowed the development of an amperometric method to determine glycerol in biodiesel samples in the range 0.05 to 1.33 mmol L-1 with a detection limit of 20 µmol L-1. The determination of the analyte in a castor biodiesel sample employing a single copper microelectrode was carried out. The four part of this thesis shows results on the synthesis, electrochemical characterization and use of a glassy carbon (GC) electrode modified with multi-wall carbon nanotubes (MWCNT) decorated with palladium (Pd) for the electrochemical oxidation of methanol, ethanol and glycerol in 1.0 mol L-1 KOH solution. The results showed that MWCNT/Pd is a good electrocatalyst for methanol, ethanol and glycerol oxidation in alkaline medium, with highest activity toward glycerol oxidation. With optimized experimental conditions, an amperometric method was developed for the determination of glycerol in biodiesel samples, in the range of 0.06 to 24 mmol L-1 and detection limit of 30 µmol L-1. Biodiesel samples were successfully analyzed by the standard addition method using the GC/MWCNT/Pd film electrode.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-08-18
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.