• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.46.2019.tde-09032020-083028
Documento
Autor
Nome completo
Andrei Martins Surkov
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2019
Orientador
Banca examinadora
Angnes, Lucio (Presidente)
Isidoro, Roberta Alvarenga
Oliveira, Lucia Codognoto de
Título em português
Desenvolvimento de eletrodos compósitos de carbono e poliestireno para aplicações eletroanalíticas
Palavras-chave em português
Amperometria
Eletrodo compósito
Eletrodo de baixo custo
Grafitepoliestireno
Resumo em português
Um novo eletrodo compósito (G-PS) foi preparado a partir de grafite e poliestireno (isopor). As partículas de grafite foram suspensas em clorofórmio e o poliestireno foi adicionado à mistura para sua completa dissolução. O clorofórmio foi volatilizado a 80°C, e acetona foi adicionada para o amolecimento do material resultante, conferindo alto grau de plasticidade ao mesmo, favorecendo assim a construção dos eletrodos compósitos. A proporção de grafite foi otimizada com base nos sinais voltamétricos obtidos com o par reversível Fe(CN)63−/Fe(CN)64−. O compósito contendo 75% de grafite (m/m) mostrou o melhor desempenho, considerando sinal, estabilidade mecânica e alta reprodutibilidade de resposta eletroquímica. Estudos de homogeneidade do compósito indicaram boa uniformidade ao longo de um mesmo eletrodo e também entre eletrodos produzidos em diferentes ensaios. A caracterização eletroquímica destes eletrodos demonstrou que os processos são governados por transporte difusional de massa para ferricianeto de potássio. A resistência de transferência de carga e a resposta eletroquímica do eletrodo compósito foi diretamente comparada com eletrodo de carbono vítreo (GCE) e eletrodo de pasta de carbono (CPE). Aplicações do eletrodo G-PS como sensor eletroquímico foram feitas para paracetamol e dipirona. Análises destes fármacos foram realizadas associando o eletrodo G-PS e um sistema de análise por injeção em fluxo. Os resultados obtidos foram validados frente aos métodos padrões descritos nas farmacopeias americana e brasileira e também comparados com método por UV-Vis. Os limites de detecção calculados foram 0,084 e 0,67 µmol L-1 para paracetamol e dipirona, respectivamente. A faixa linear de trabalho para o paracetamol foi 0,28 204 µmol L-1, enquanto para dipirona foi 2,7 86 µmol L-1.
Título em inglês
Development of carbon and polystyrene composite electrodes for electroanalytical applications
Palavras-chave em inglês
Amperometry
Composite electrode
Graphite-polystyrene
Low cost electrode
Resumo em inglês
A new composite electrode (G-PS) was prepared from graphite and polystyrene (Styrofoam). The graphite particles were suspended in chloroform and the polystyrene was added to the mixture for complete dissolution. Chloroform was volatilized at 80ºC and acetone was added to soften the resulting material, giving it a high degree of plasticity, thus favoring the construction of the composite electrodes. The graphite ratio was optimized based on the voltammetric signals obtained with the reversible pair Fe(CN)63−/Fe(CN64−. The composite containing 75% graphite (w/w) showed the best performance considering signal, mechanical stability and high reproducibility of electrochemical response. Composite homogeneity studies indicated good uniformity across the same electrode and also between electrodes produced in different assays. The electrochemical characterization of these electrodes demonstrated that the processes are governed by diffusional mass transport for potassium ferricyanide. The resistance of charge transfer and the electrochemical response of the composite electrode were directly compared with glassy carbon electrode (GCE) and carbon paste electrode (CPE). Applications of the G-PS electrode as electrolytic sensor were made for acetaminophen and dipyrone quantification. Analyses of these drugs were performed by associating the G-PS electrode and a flow injection system. The results obtained were validated against the standard methods described in the American and Brazilian pharmacopoeias and also compared with the UV-Vis method. The detection limits calculated were 0.084 and 0.67 µmol L-1 for acetaminophen and dipyrone respectively. The linear working range for acetaminophen was 0.28 - 204 µmol L-1, while for dipyrone it was 2.7 - 86 µmol L-1.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2020-08-07
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.