Master's Dissertation
DOI
https://doi.org/10.11606/D.46.2018.tde-23112018-165441
Document
Author
Full name
Adriana De Donato
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2001
Supervisor
Committee
Gutz, Ivano Gebhardt Rolf (President)
Cantagallo, Maria Inês Costa
Pedrotti, Jairo Jose
Title in Portuguese
Desenvolvimento, comparação e aplicação forense de sistemas de injeção em banho e injeção em fluxo, com detecção voltamétrica de chumbo em eletrodo de mercúrio
Keywords in Portuguese
ASV
BIA
Eletroanalítica
FIA
Forense
Método eletroquímico
Química analítica
Química forênsica
Voltametria
Abstract in Portuguese
Para determinar baixas concentrações de chumbo, oriundo de resíduos de disparo de armas de fogo, aplicou-se a voltametria de redissolução anódica, ASV, com pulso diferencial, PD, para detecção do metal em eletrodo de gota pendente de mercúrio, EGPM. A etapa de redução se dava a -0,6 V vs. Ag/AgCl, durante 25s, com imediata varredura até -0,3V vs. Ag/AgCl. O pico de reoxidação do chumbo surgia a -0,42V vs. Ag/AgCl. A injeção de amostras foi bastante facilitada pela aplicação do sistema de análise por injeção em banho, BIA onde um pequeno volume de amostra é injetado, com o auxílio de um micropipetador automático, diretamente sobre um detector imerso em um volume várias vezes maior que aquele da amostra. Com o intuito de estender a técnica ao EGPM comercial, um adaptador simples, em forma de J, foi desenvolvido e aplicado, o qual dirige o fluxo descendente do micropipetador para cima, diretamente sobre a gota de mercúrio. Foi dada a presença de chumbo, da ordem de 1 ppm, quando se amestrava as mãos encontro de voluntários, do Instituto de Criminalística da Polícia Científica do Estado de São Paulo, com tiras de fita crepe antes e depois de um conjunto de disparos. A extração do chumbo foi feita através da agitação de cada tira de fita crepe, apoiada em tela de Nylon®, com uma mistura de clorofórmio e HCl 0,1 M, com a fase aquosa sendo levada a posterior análise. Outros métodos de coleta também foram testados. Nota-se, também, que é possível determinar o mesmo analito em sistemas de injeção em fluxo, após desoxigenação do eletrólito suporte. Com o uso da técnica de pulso reverso, a desoxigenação pode se tornar desnecessária.
Title in English
Development, comparison and forensic application of injection and flow injection systems with voltammetric detection of lead in mercury electrode
Keywords in English
Analytical chemistry
ASV
BIA
Electroanalytical
Electrochemical method
FIA
Forensic
Forensic chemistry
Voltammetry
Abstract in English
In order to determine low concentrations of lead, originated from gunshot residues, anodic stripping voltammetry, ASV, with differential pulse, DP, was applied to detect the metal in a hanging mercury drop electrode, HMDE. The reduction step was done at -0.6 V vs. Ag/AgCl, for 25s, followed by the immediate scan up to -0.3V vs. Ag/AgCl. The reoxidation current peak appeared at -0.42V vs. Ag/AgCl. The injection of samples was greatly facilitated by the application of the batch injection analysis system, BIA, where a small sample volume is injected, with the aid of an automatic micropipettor, directly onto the detector, which is immersed in a volume many times larger than the sample. Aiming the application of the technique with commercial HMDE, a simple J-shaped adapter was developed and applied, which directs upwards the descending flow of the micropipettor, rightly over the mercury drop surface. The presence of lead was observed at around 1 ppm, after sampling the hands of volunteers, from the Institute of Criminalistics of the Scientific Police of São Paulo State, with strips of adhesive tapes before and after a set of gunshots. Lead extraction was performed shaking each strip, over a Nylon® screen, in a mixture containing chloroform and HCl 0.lM, with the posterior analysis of the aqueous phase. Other collection methods were also tried. It is also possible to determine the same analyte in a flow injection system, after the deoxygenation of the supporting electrolyte. With the aid of the reverse pulse technique, the deoxygenation may become unnecessary.
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2018-11-23