Thèse de Doctorat
DOI
https://doi.org/10.11606/T.46.2019.tde-21022019-103823
Document
Auteur
Nom complet
Renato Camargo Matos
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2001
Directeur
Jury
Angnes, Lucio (Président)
Ferreira, Sérgio Luis Costa
Fungaro, Denise Alves
Machado, Sergio Antonio Spinola
Masini, Jorge Cesar
Titre en portugais
Sistemas amperométricos empregando matrizes de microeletrodos e análises simultâneas
Mots-clés en portugais
Amperometria
Análise simultânea
Microeletrodos
Multipotenciostato
Química ambiental
Química analítica instrumental
Resumé en portugais
No presente trabalho são descritos métodos versáteis para determinações simultâneas multicomponentes. Estes são baseados num sistema de detecção multicanal acoplado a célula em fluxo contendo um conjunto de microeletrodos modificados. O primeiro método mostra a quantificação amperométrica em fluxo de ácido ascórbico (AA), dopamina (DA), epinefrina (EP) e dipirona (DI) em misturas (na faixa de µg g-1). Neste trabalho foi utilizado um conjunto de microeletrodos de ouro limpos e modificados, independentemente, com diferentes metais nobres (Pt, Pd e uma mistura equimolar de Pd e Pt), associados com métodos de calibração multivariada. As análises de amostras sintéticas e formulações farmacêuticas contendo AA e DI apresentaram valores muito similares aos encontrados com a iodometria clássica. O método apresentou um erro médio absoluto (em µg g-1) de 0,3, 0,1, 0,4 e 0,3 para AA, DA, EP e DI, respectivamente, para a regressão linear múltipla e 0,3, 0,4, 0,4 e 0,2 para AA, DA, EP e DI, respectivamente, para a regressão por mínimos quadrados parciais. O segundo trabalho apresenta um método para determinação amperométrica diferencial de peróxido de hidrogênio em águas de chuvas em associação com análise por injeção em fluxo e imobilização de catalase em reator tubular usando glutaraldeído e resina amberlite IRA - 743 como suporte. A curva de calibração para o peróxido de hidrogênio foi linear na faixa de concentração de 1 a 10 x 10-6 mol L-1 com um desvio relativo padrão (RSD) < 1%. O limite de detecção do método foi calculado em 2,9 x 10-7 mol L-1. As análises de águas de chuvas foram comparadas com amperometria usando microeletrodo de mercúrio e espectrofotometria, sendo que os resultados mostraram uma boa correlação. O terceiro método descreve a determinação amperométrica simultânea em fluxo de glicose e ácido úrico, usando dois microeletrodos com diferentes composições (Pt e Pt+glicose oxidase+acetato de celulose) e detecção multicanal. A curva de calibração para a glicose foi linear na faixa de concentração de 1 a 10 x 10-4 mol L-1 com um desvio relativo padrão (RSD) < 1%. O limite de detecção do método foi calculado em 5 x 10-5 mol L-1. As análises de amostras sintéticas foram comparadas com o método espectrofotométrico, mostrando uma boa concordância entre os resultados obtidos.
Titre en anglais
Amperometric system using array of microelectrode and simultaneous determinations
Mots-clés en anglais
Amperometry
Environmental chemistry
Instrumental analytical chemistry
Microelectrodes
Multipotentatstate
Simultaneous analysis
Resumé en anglais
In the present work, versatile methods for simultaneous amperometric multicomponent analysis are described. They are based on a multi-channel detection system, coupled to a flow cell containing an array of modified microelectrodes. The first method shows the flow injection amperometric quantification of ascorbic acid (AA), dopamine (DA), epinephrine (EP) and dipyrone (DI) in mixtures (in the µg g-1 range). This work was successfully performed by using an array of microelectrodes bare and with units modified by the electrodeposition of different noble metals (platinum, palladium or a mixture of platinum+palladium), together with multivariate calibration analysis. The analysis of synthetic samples and pharmaceutical compounds containing AA and DI led to very similar values to those obtained by the classical iodometric analysis. The average absolute errors (in µg g-1) calculated for each analyte were 0.3, 0.1, 0.4 and 0.3 for AA, DA, EP and DI, respectively, for multiple linear regression and 0.3, 0.4, 0.4 e 0.2 for AA, DA, EP and DI , respectively, for partial least square regression. The second study presents a method for differential amperometric determination of hydrogen peroxide in rainwater in association with flow injection analysis and immobilized catalase enzymes in a tubular reactor using glutaraldeyde and amberlite IRA - 743 which support. The calibration curves for hydrogen peroxide standards was linear in the concentration range from 1 to 10 x 10-6 mol L-1 with a relative standard deviation (RSD) < 1 %. The detection limit was calculated as 2.9 x 10-7 mol L-1. The rainwater samples analyses where compared with the amperometric using mercury microelectrode and spectrophotometric methods, showing very good correlation between all the methods. The third method describes the flow injection amperometric determination of glucose and uric acid simultaneously, using two microelectrodes with different composition (platinum and platinum+glucose oxidase+cellulose acetate) and a multi-channel detection system. The calibration curves for glucose standards was linear in the concentration range from 1 to 10 x 10-4 mol L-1 with a relative standard deviation (RSD) < 1 %. The detection limit was calculated as 5 x 10-5 mol L-1. The analyses of synthetic samples were compared with the spectrophotometric method, showing very good correlation between the methods.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2019-02-21
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.