• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.46.1997.tde-16072008-093734
Documento
Autor
Nombre completo
Carlos Sergio da Silva
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 1997
Director
Tribunal
Oliveira, Elisabeth de (Presidente)
Arcuri, Arline Sydneia Abel
Machado, Jorge Mesquita Huet
Massaro, Sérgio
Silva, Mary Rosa Rodrigues de Marchi Santiago da
Título en portugués
Um estudo crítico sobre a saúde dos trabalhadores de galvânicas, por meio das relações entre as avaliações ambientais, biológicas e otorrinolaringológicas
Palabras clave en portugués
Avaliação ambiental
Avaliação otorrinolaringológica
Monitoramento biológico
Toxicologia clínica
Toxicologia ocupacional
Resumen en portugués
Avaliação ambiental, biológica e otorrinolaringológica foi realizada em 461 trabalhadores de 22 galvânicas com diferentes processos de tratamento de superficie: anodização, cromo duro, cromo decorativo, zincagem e processos diversos. O ar do ambiente de trabalho foi coletado individualmente e em pontos fixos, durante a semana de trabalho, para se avaliarem névoas sulfúricas e clorídricas, além daquelas referentes a cromo, níquel e zinco. Amostras de urina dos trabalhadores, foram coletadas no início e final do período de trabalho, para se determinar a concentração de Cr-U, Ni-U e Zn-U. Utilizou-se a técnica de espectrofotometria de absorção atômica com forno de grafite para determinação de Cr-U e Ni-U; o Zn-ar, Ni-ar e o Zn-U foram determinados pela mesma técnica mas utilizando-se na atomização do analito, a chama. Os limites de detecção foram semelhantes aos encontrados na literatura internacional. Os resultados ambientais situaram-se, na sua maioria, bem abaixo dos limites de tolerância estabelecido pela legislação brasileira e internacional, ressaltando-se que, dos contaminantes avaliados, existem LTs apenas para o cromo e névoas clorídricas enquanto que limite biológico apenas para o Cr-U. Os resultados otorrinolaringológicos dos trabalhadores foram surpreendentes, considerando-se todos os processos avaliados: 35,5% de lesões médias e avançadas nas vias aéreas superiores e 40,1% de lesões iniciais e inespecíficas. Estes resultados relacionados com os obtidos nas avaliações ambientais e biológicas, dão-nos a certeza de que os limites de tolerância não são parâmetros seguros para proteger a saúde do trabalhador.
Título en inglés
A study relating to electroplaters´ health through relationships between environmental, biological, nose and throat evaluations
Palabras clave en inglés
Biological monitoring
Environmental evaluation
Nose and throat evaluation
Resumen en inglés
Environmental, biological, and otolaryngology evaluations were carried out on 461 workers from 22 electroplaters with different processes for the treatment of surfaces. Air from the working environment was collected both individually end from fixed points, during the working week, for evaluation of sulphuric and hydrochloric acid mists, as well as for mists of chrome, nickel and zinc. Samples of worker's urine were collected at the beginning and end of the work shift in order to determine the concentrations of U-Cr, U-Ni and U-Zn. Electrothermal atomic absorption spectrometry was used to determine air-Cr, U-Cr, and U-Ni; air-Zn, air-Ni and U-Zn were determined using the atomic absorption spectrometry. The detection limits were similar to those found in the intemational literature. The environmental and biological results were in most cases below the limits set by the Brazilian and International legislation. Note that, of the contaminants evaluated, TLs are available for only chrome and hydrochloric acid mists and Biological Limits for only U-Cr. The otolaryngology results for the workers were surprising, taking into account all of the processes evaluated: 35.5% with medium and advanced lesions of the upper respiratory tract, and 40.1% with initial or non-specific lesions. These results, taken together with those obtained in the environmental and biological evaluations show that the tolerance limits are not safe parameters to protect worker's health.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2008-07-21
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.