• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.46.2010.tde-10112010-112208
Document
Auteur
Nom complet
Ana Paula Ruas de Souza
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2010
Directeur
Jury
Bertotti, Mauro (Président)
Freire, Renato Sanches
Pedrotti, Jairo José
Titre en portugais
Determinação de íons cádmio e zinco no sistema estuarino - lagunar de Cananéia - Iguape por voltametria de redissolução anódica
Mots-clés en portugais
Água estuarina
Cádmio
Chumbo
Microeletrodo
Stripping
Voltametria
Zinco
Resumé en portugais
A determinação dos íons Cd(II) e Zn(II) foi realizada em amostras de águas estuarinas por voltametria de redissolução anódica utilizando microeletrodo de fibra de carbono (raio =3 µm). O filme de bismuto foi depositado in situ, simultaneamente com os analitos em microeletrodo sob as condições otimizadas. O intervalo linear da curva de calibração para ambos os íons metálicos foi 0,5 -10,0 nmol L-1 e os limites de detecção de Cd(II) e Zn(II) foram estimados em 17 e 52 pmol L-1, respectivamente. A precisão dos resultados fornecidos empregando-se o microeletrodo de filme de bismuto (BiFME) foi avaliada pela realização de experimento com uma amostra certificada e teste de recuperação. A utilidade da metodologia foi demonstrada aplicando o BiFME para determinar baixas concentrações de Cd(II) e de Zn(II) em água do estuário.
Titre en anglais
Determination of cadmium and zinc ions in the Lagoon - Estuarine System Cananéia - Iguape by anodic stripping voltammetry
Mots-clés en anglais
Cadmium
Estuarine water
Lead
Microelectrode
Stripping
Voltammetry
Zinc
Resumé en anglais
A bismuth-film electrode for use in anodic stripping voltammetry was employed in order to quantify Cd(II) and Zn(II) in estuarine water samples. The bismuth film was deposited in situ simultaneously with the analytes onto a carbon fiber disc microelectrode (radius = 3 µm). Under the optimised conditions, calibration plots for both metallic ions were obtained in the range 0.5 to 10.0 nmol L-1 and the limits of detection for Cd(II) and Zn(II) were estimated as 17 and 52 pmol L-1, respectively. The accuracy of the results supplied by the bismuth film microelectrode (BiFME) was assessed by performing experiment with a certified sample and addition-recovery experiments. The usefulness of the methodology was demonstrated by applying the BiFME to measuring the Cd(II) and Zn(II) content in estuarine water.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
errataAnaPaulaRuas.pdf (170.12 Kbytes)
Date de Publication
2011-01-20
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.