• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.46.2010.tde-10112010-112208
Documento
Autor
Nombre completo
Ana Paula Ruas de Souza
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2010
Director
Tribunal
Bertotti, Mauro (Presidente)
Freire, Renato Sanches
Pedrotti, Jairo José
Título en portugués
Determinação de íons cádmio e zinco no sistema estuarino - lagunar de Cananéia - Iguape por voltametria de redissolução anódica
Palabras clave en portugués
Água estuarina
Cádmio
Chumbo
Microeletrodo
Stripping
Voltametria
Zinco
Resumen en portugués
A determinação dos íons Cd(II) e Zn(II) foi realizada em amostras de águas estuarinas por voltametria de redissolução anódica utilizando microeletrodo de fibra de carbono (raio =3 µm). O filme de bismuto foi depositado in situ, simultaneamente com os analitos em microeletrodo sob as condições otimizadas. O intervalo linear da curva de calibração para ambos os íons metálicos foi 0,5 -10,0 nmol L-1 e os limites de detecção de Cd(II) e Zn(II) foram estimados em 17 e 52 pmol L-1, respectivamente. A precisão dos resultados fornecidos empregando-se o microeletrodo de filme de bismuto (BiFME) foi avaliada pela realização de experimento com uma amostra certificada e teste de recuperação. A utilidade da metodologia foi demonstrada aplicando o BiFME para determinar baixas concentrações de Cd(II) e de Zn(II) em água do estuário.
Título en inglés
Determination of cadmium and zinc ions in the Lagoon - Estuarine System Cananéia - Iguape by anodic stripping voltammetry
Palabras clave en inglés
Cadmium
Estuarine water
Lead
Microelectrode
Stripping
Voltammetry
Zinc
Resumen en inglés
A bismuth-film electrode for use in anodic stripping voltammetry was employed in order to quantify Cd(II) and Zn(II) in estuarine water samples. The bismuth film was deposited in situ simultaneously with the analytes onto a carbon fiber disc microelectrode (radius = 3 µm). Under the optimised conditions, calibration plots for both metallic ions were obtained in the range 0.5 to 10.0 nmol L-1 and the limits of detection for Cd(II) and Zn(II) were estimated as 17 and 52 pmol L-1, respectively. The accuracy of the results supplied by the bismuth film microelectrode (BiFME) was assessed by performing experiment with a certified sample and addition-recovery experiments. The usefulness of the methodology was demonstrated by applying the BiFME to measuring the Cd(II) and Zn(II) content in estuarine water.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
errataAnaPaulaRuas.pdf (170.12 Kbytes)
Fecha de Publicación
2011-01-20
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.