Master's Dissertation
DOI
https://doi.org/10.11606/D.46.1999.tde-10102014-123933
Document
Author
Full name
Clóvis Lúcio da Silva
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 1999
Supervisor
Committee
Masini, Jorge Cesar (President)
Angnes, Lucio
Bevilacqua, Jose Eduardo
Title in Portuguese
Emprego de análise por injeção seqüencial (SIA) com detecção eletroquímica na determinação de metais pesados extraíveis de sedimentos
Keywords in Portuguese
Análise sequencial; Detecção eletroquímica
Eletroquímica (Métodos analíticos)
Metais pesados (Determinação; Análise química)
Metais pesados; Sedimento
Método eletroquímico (Análise química)
Química ambiental
Química analítica quantitativa
Abstract in Portuguese
Estudou-se a especiação dos metais pesados (Cu, Cd, Cr, Zn, Pb e Ni) em sedimentos do rio Tietê, coletados nos reservatórios de Rasgão, Tecelagem e Barra Bonita. Para isto, adotou-se o protocolo de extração seqüencial proposta por Community Bureau of Reference (BCR), que consiste em três etapas de tratamento, as soluções extratores utilizados foram: etapa 1, solução de ácido acético 0,11 mol/L; Etapa 2, solução de cloridrato de hidroxilamina 0,1 mol/L pH 2 (ajustado com HNO3); Etapa 3, ataque com peróxido de hidrogênio em meio ácido e posterior extração dos metais com solução de acetato de amônio pH 2 (ajustado com HNO3). Nas mesmas amostras efetuou-se uma extração com ácido clorídrico 0,1 mol/L, no sentido de avaliar a concentração de metais potencialmente biodisponíveis. Realizou-se ainda a determinação do teor total de metais. Tanto a extração seqüencial como a extração parcial em ácido diluído foram conduzidas em ambientes anaeróbico (mantendo o EH da amostra) e aeróbicos (após secagem em estufa - simulando material dragado e depositado às margens do rio). As concentrações dos metais presentes nos extratos foram determinadas através das técnicas de absorção atômica, espectrometria de emissão atômica, voltametria de redissolução anódica com eletrodo de gota pendente e a técnica proposta por este trabalho, voltametria de redissolução anódica com eletrodo de filme de mercúrio acoplada ao sistema de injeção seqüencial. A técnica de voltametria de redissolução anódica acoplada ao sistema de injeção sequencial apresentou vantagens em relação a voltametria de redissolução com eletrodo de gota pendente, apresentando maior reprodutibilidade e sensibilidade, redução do tempo de análise e consumo de reagentes, e completa automação dos parâmetros instrumentais, como: vazão, número de reagentes, volumes e seqüência dos reagentes aspirados.
Title in English
The use of sequential injection analysis with electrochemical detection for determination of heavy metals extractable from sediments
Keywords in English
Analytical chemistry quantitative
Electrochemical method (Chemical analysis)
Electrochemistry (Analytical Methods)
Environmental chemistry
Heavy metals (Determination; Chemical analysis)
Heavy metals; Sediment
Sequential analysis; Electrochemical detection
Abstract in English
Speciation of heavy metals (Cu, Pb, Cd, Zn, Ni and Cr) in sediments of the Tietê river (SP), collected at Rasgão, Tecelagem e Barra Bonita reservoirs, was studied by the sequential extraction protocol proposed by the Community Bureau of Reference (BCR). This protocol is composed of three steps, that use the following reagent extractors. Step1: 0,11 mol/L acetic acid. Step 2: Hydroxylamine hydrochloride, acidified to pH 2 with nitric acid. Step 3: Oxidation with acidified 30 % (v/v) hydrogen peroxide followed by extraction with 1mol/L ammonium acetate acidified to pH 2 with nitric acid. Samples were also extracted with 0.10 mol/l hydrochloric acid in order to evaluate the bioavailable metal concentrations. The total concentration of metals was also determined. The sequential extraction and the extraction with hydrochloric acid were performed in anoxic (keeping the negative Eh of samples, as in the time of sampling) and oxidant conditions (after drying samples at 60ºC in the atmosphere, simulating dredged material). Metal determination was performed by Flame Atomic Absorption Spectrometry (FAAS), Induced Coupled Plasma-Atomic Emission Spectrometry (ICP-EAS), Anodic Stripping Voltammetry with the Mercury Hanging Drop Electrode (ASV-HMDE), and the technique proposed in this work: ASV automated by Sequential Injection (ASV-SI) using the Thin Film Mercury Electrode (TFME). The proposed technique presented improved reproducibility and shorter time of analysis in comparison to conventional ASV-HMDE. In addition, the ASV-SI permits easy and fast change of operational parameters such as flow rate and sample volume, that have direct influence on the deposition time.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2014-10-10
 
WARNING: Learn what derived works are clicking here.