• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.45.2011.tde-19072011-141251
Documento
Autor
Nombre completo
Luis Roberto Pereira de Paula
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2011
Director
Tribunal
Hirata Junior, Roberto (Presidente)
Gutierrez, Marco Antonio
Jackowski, Marcel Parolin
Título en portugués
Segmentação de imagens SPECT/Gated-SPECT do miocárdio e geração de um mapa polar.
Palabras clave en portugués
Bull's Eye
Mapas Polares
Medicina Nuclear
Paradigma de Beucher-Meyer
Perfusão Miocárdica.
Segmentação Morfológica
SPECT
Transformada de Hough
Watershed
Resumen en portugués
Tomografia computadorizada por emissão de fóton único (SPECT) é uma modalidade da medicina nuclear baseada na medida da distribuição espacial de um radionuclídeo. Esta técnica é amplamente utilizada em cardiologia para avaliar problemas de perfusão miocárdica, relacionados ao fluxo sanguíneo nas artérias coronárias. As imagens SPECT proporcionam melhor separação das regiões do miocárdio e facilitam a localização e a definição dos defeitos de perfusão. Um dos grandes desafios em estudos SPECT é a eficiente apresentação da informação, uma vez que um único estudo pode gerar imagens de centenas de cortes a serem analisados. Para resolver este problema, são utilizados mapas polares (também conhecidos como gráficos Bulls Eye). Mapas polares são construídos a partir de cortes tomográficos do ventrículo esquerdo e apresentam as informações dos exames de forma sumarizada, em uma imagem bidimensional. Essa dissertação apresenta um método para segmentação do ventrículo esquerdo em estudos SPECT do miocárdio e a construção de mapas polares. A segmentação do ventrículo esquerdo é realizada para facilitar o processo de geração automática de mapas polares. O método desenvolvido utiliza a transformada watershed, no contexto do paradigma de Beucher-Meyer. Para visualização dos resultados, foi desenvolvida uma aplicação, chamada Medical Image Visualizer (MIV). O MIV será disponibilizado como projeto Open Source, podendo ser livremente utilizado e/ou modificado pela comunidade de usuários, desenvolvedores e pesquisadores.
Título en inglés
Segmentation of myocardial SPECT/Gated-SPECT images and polar map generation.
Palabras clave en inglés
Beucher-Meyer Paradigm
Bull's Eye
Hough Transform
Morphological Segmentation
Myocardial Perfusion.
Nuclear Medicine
Polar Maps
SPECT
Watershed
Resumen en inglés
Single photon emission computed tomography (SPECT) is a nuclear medicine tomographic imaging technique based on the measurement of spatial distribution of a radionuclide. This technique is widely used in cardiology to assess myocardial perfusion problems related to blood flow in coronary arteries. SPECT images provide better separation of regions of the myocardium and facilitate the location and definition of perfusion defects. One of the major challenges in SPECT studies is the efficient presentation of information, since a single study can generate hundreds of images of slices to be analyzed. To address this issue, polar maps (also known as Bulls Eye display) are used. Polar maps are built from slices of the left ventricle and provide summarized information of exams in a two dimensional image. This dissertation presents a method for the segmentation of the left ventricle in myocardial SPECT studies and the construction of polar maps. The segmentation of the left ventricle is performed to facilitate the process of automatic generation of polar maps. The method uses the watershed transform, in the context of the Beucher-Meyer paradigm. To display the results, it was developed an application called Medical Image Visualizer (MIV). MIV will be available as an Open Source project and the communities of users, developers and researchers will be able to freely use and/or modify the application.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
dissertacao.pdf (6.16 Mbytes)
Fecha de Publicación
2011-11-08
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.