Título en portugués
Metodologia geofísica para contaminação por hidrocarbonetos - estudo de caso em posto de combustíveis
Palabras clave en portugués
Contaminação
Hidrocarbonetos
Métodos geofísicos
Posto de combustíveis
Resumen en portugués
A água subterrânea abastece grande parte da população e sua contaminação é assunto de interesse público. Os postos de combustíveis são fontes potenciais de contaminação, devido à sua extensa malha de distribuição e pelo armazenamento de produto ser predominantemente subterrâneo. Dentre os métodos para detecção de hidrocarbonetos, os geofísicos proporcionam investigação em maiores extensões, com mais rapidez e menor custo. Este estudo apresenta os resultados de quatro métodos geofísicos (eletrorresistividade, polarização induzida, georradar e eletromagnético EM-34) na investigação de dois perfis a jusante de um posto de combustível com histórico de vazamento. Os objetivos foram de detectar a pluma de contaminação e identificar qual dos métodos apresenta os melhores resultados nesta situação. A eletrorresistividade apresentou a melhor correlação com a zona contaminada e com as análises químicas. Os dados da polarização induzida também se relacionaram com a pluma. Os valores do sistema EM-34 ficaram aquém das expectativas. Os do georradar não possibilitaram nenhuma correlação com o substrato contaminado, certamente devido a pouca profundidade de penetração. Foi constatado que a contaminação por hidrocarbonetos não oferece assinatura geoelétrica previsível, devido às condições dinâmicas do campo e suas inter-relações. Enquanto muitos trabalhos associam baixas resistividades aos vazamentos antigos, outros trabalhos mostram o inverso. Neste estudo, a anomalia encontrada apresentou alta resistividade associada às cargabilidades mais altas.
Título en inglés
Geophysical methods to hydrocarbon contamination - case history in service station
Palabras clave en inglés
Contamination
Geophysical methods
Hydrocarbon
Service station
Resumen en inglés
A large portion of the population is supplied with groundwater, and this is a matter of public interest. Gas stations are potential sources of contamination for its extensive distribution network and for the underground storage. Among the existing methods for hydrocarbon detection, the geophysical ones provide a larger range, faster results at smaller costs. This work presents the results of four geophysical methods (electrical resistivity, induced polarization, ground penetrating radar and electromagnetic EM-34) applied to the study of two profiles downwards of a leaking gas station. The objectives were detecting the contamination plume and identify which of the methods employed presents the best results on this site. The electrical resistivity method presented the best correlation with the contaminated zone and chemical analysis. The results of the induced polarization were also associated with the contamination plume. Values obtained with the EM-34 didn?t fulfill the expectations. GPR data didn?t correlate with the contaminated substrate, certainly due to the shallow penetration depth. It was observed that the hydrocarbon contamination does not offer a predictable geoelectrical signature, due to the dynamic conditions of the field and its inter relations. Whilst several paper associate low resistivities to older leakages, in other papers it was found the opposite. In this case study, the anomaly has shown characteristics of high resistivity associated to higher chargeabilities.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
SGM.pdf (3.42 Mbytes)
Fecha de Publicación
2007-10-31
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.