Tesis Doctoral
DOI
https://doi.org/10.11606/T.44.2007.tde-18122007-110918
Documento
Autor
Nombre completo
Virginia Maria Tesone Coelho
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2007
Director
Tribunal
Duarte, Uriel (Presidente)
Hypolito, Raphael
Mancuso, Pedro Caetano Sanches
Pacheco, Alberto
Rosa Filho, Ernani Francisco da
 
Título en portugués
Potencial de contaminação de aqüífero freático por esgoto doméstico-quantificação do decaimento bacteriológico
Palabras clave en portugués
Aqüífero freático
Contaminação
Resumen en portugués
Esta pesquisa, para fins de determinação do comportamento de microrganismos termotolerantes em águas de aqüífero freático, foi realizada em terrenos aluviais na ETE de Vila dos Remédios, Salesópolis - SP. No local foram instalados uma vala de infiltração para esgoto doméstico bruto e 55 poços de monitoração da água subterrânea, de modo a caracterizar a pluma de contaminação em seu deslocamento ao longo da área ensaiada. Seguindo as normas técnicas de coleta e análise físico-químicabacteriológica das águas subterrâneas foram executadas, com o intuito de conhecimento específico do local de pesquisa, 55 poços com amostragem e caracterização litológica do solo local até profundidade de 2,5m, prospecção geofísica eletrorresistiva de caracterização inicial e eletromagnética (EM-31) de acompanhamento do deslocamento da pluma de contaminação, amostragem e caracterização físico-química-bacteriológica do esgoto bruto e das águas subterrâneas. Dois mil litros de esgoto bruto, coletado diretamente da rede, foi introduzido no solo através de vala de infiltração, de modo a caracterizar uma injeção pontual, sem transbordamento e de maneira contínua, com uma taxa de infiltração de aproximadamente 80L/h. O deslocamento da pluma de contaminação formada no aqüífero freático saturado foi monitorado através de amostras de água coletadas sistematicamente, ao longo do tempo, cujos resultados permitiram calcular a velocidade de deslocamento da pluma, como sendo de 8,6 x 10-4 cm/s e, um decaimento de organismos termotolerantes em ambiente de aqüífero saturado de 21dias. Estes resultados permitem o cálculo direto de perímetros de proteção aplicáveis a poços e fontes naturais de captação de água subterrânea, no caso de possibilidades de contaminação por esgoto domiciliar, neste contexto litológico.
 
Título en inglés
Potential of freatic aquifer contamination by domestic sewage-quantification of the bacteriological decay
Palabras clave en inglés
Contamination
Freatic aquifer
Resumen en inglés
The objective of this research was to study the behavior of thermo-tolerant microorganisms in the phreatic aquifer, in alluvial terrains where the sewage was disposed. The study area was close to the sewage treatment plant of Vila dos Remédios, Salesópolis, SP. An injection trench and 55 monitoring wells were installed in the area. The sewage was discharged in the trench and samples of the groundwater were taken to study the contamination plume migration and its physic-chemical and bacteriological characteristics through the time. The wells were constructed with 2.0 meters of depth and the samples were used to characterize the lithological setting. An initial eletroresistivity survey was performed and, together with the groundwater sampling, electromagnetic survey (EM-31) was periodically conducted to evaluate the plume migration. Two thousand liters of domestic sewage "in natura" was introduced in the trench to characterize a punctual injection, with a continuous infiltration rate of 80L/h. The migration of the contamination plume was continuously monitored during nine months and the results allowed calculating the migration speed as being 7,67x10-4 cm/s. The thermo-tolerant microorganisms were extinguished 21 days after the sewage injection. These results allow calculating the protection perimeter applied to groundwater wells and natural springs to avoid sewage contamination in the same lithological context.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
VMTC.pdf (12.58 Mbytes)
Fecha de Publicación
2008-05-15
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores.
CeTI-SC/STI
© 2001-2024. Biblioteca Digital de Tesis y Disertaciones de la USP.