• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.43.2001.tde-27052021-175902
Document
Auteur
Nom complet
Fábio Eduardo Rosa Campolim
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2001
Directeur
Jury
Nussenzveig, Paulo Alberto (Président)
Cruz, Flávio Caldas da
Figueiredo Neto, Antonio Martins
Titre en portugais
Resfriamento e aprisionamento magneto-ótico de átomos de rubídio.
Mots-clés en portugais
ÁTOMOS
FÍSICA ATÔMICA
Resumé en portugais
Apresentamos a construção de uma Armadilha Magneto-Ótica MOT (Magneto-optical Trap) para átomos de Rubídio. São discutidos os princípios do aprisionamento de átomos neutros, a instrumentação dos lasers de diodo utilizada nesta experiência, e uma caracterização primária da núvem de átomos aprisionados de 'ANTPOT. 85 Rb' e de 'ANTPOT. 87 Rb'. Desenvolvemos um sistema de ampliação ótica multicanal para ser utilizado neste aprisionamento, que denominamos DMOPA (Double Master Oscillator Power Amplifier). Encontramos neste sistema uma instrumentação simples e bem adaptada para o aprisionamento magneto-ótico. Por fim, discutimos as possíveis aplicações da armadilha em nosso laboratório.
Titre en anglais
Resfriamento e aprisionamento magneto-ótico de átomos de rubídio.
Mots-clés en anglais
ÁTOMOS
FÍSICA ATÔMICA
Resumé en anglais
We present the construction of a Magneto-Optical Trap (MOT) for Rubidium Atoms. We discuss the principles of neutral atom trapping, the diode laser instrumentations used in this experiment, and a first caracterization of the trapped clouds of 85 Rb' and 87 Rb' atoms. We also developed a multichannel optical amplification system used for trapping, which we have denominated DMOPA (Double Master Oscillator Power Amplifier). This system is a simple and well adapted instrument dor trapping. Finally, we discuss the intended applications for the MOT in our lab.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
2001Campolim.pdf (78.95 Mbytes)
Date de Publication
2021-05-27
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.