Master's Dissertation
DOI
https://doi.org/10.11606/D.43.2007.tde-02082007-161833
Document
Author
Full name
Daniel Alexandre Baptista Bonifacio
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2007
Supervisor
Committee
Moralles, Mauricio (President)
Yoriyaz, Hélio
Yoshimura, Elisabeth Mateus
Title in Portuguese
Validação do Geant4 para a produção e detecção de raios X na faixa de energia de radiodiagnóstico
Keywords in Portuguese
Espectroscopia de raios X
Física médica
Método de Monte Carlo
Produção de raios X.
Abstract in Portuguese
Este trabalho teve como objetivo validar uma ferramenta computacional para a realização de simulações da interação de elétrons e da radiação X com a matéria, utilizando o método de Monte Carlo para possíveis estudos em radiologia diagnóstica. Para esse propósito, foi desenvolvido um programa computacional que simula a produção de radiação de um equipamento de raios X, com a finalidade de obter a distribuição de energia dos fótons que alcançam uma determinada região de interesse, sem a necessidade de medições experimentais. Outra tarefa realizada neste trabalho foi o cálculo da resposta de um detector do tipo CdTe, para possibilitar a correção de espectros medidos com esse detector em experimentos na faixa de energia de radiodiagnóstico. A ferramenta computacional escolhida para essas aplicações foi o Geant4, que é um conjunto de programas de distribuição livre relativamente novo e que é utilizado para simulações da interação da radiação com a matéria. Um dos principais diferenciais do Geant4 é o emprego da tecnologia de programação orientada a objetos e de técnicas avançadas de engenharia de software. Os resultados da etapa de simulação de espectros de energia produzidos por um equipamento de raios X mostram que o Geant4 pode ser utilizado para esta aplicação, mas com ressalvas na simulação de espectros de raios X com alvos com molibdênio para a região de mamografia, que é a situação onde as diferenças dos rendimentos de raios X característicos dos espectros simulados com os seus respectivos espectros de referência são maiores. Na etapa de simulação da detecção da radiação X por um detector do tipo CdTe são apresentados resultados com excelente acordo com os dados de referência. As diferenças encontradas devem ser mais influenciadas pelos efeitos de armadilhamento de cargas e do comportamento do campo elétrico no interior do cristal do detector, que são específicos para este detector e não fazem parte dos modelos físicos fornecidos pelo Geant4. Desta forma, a validação do Geant4 realizada neste trabalho mostrou algumas das possibilidades de uso desta versátil ferramenta na área de radiologia diagóstica.
Title in English
Validation of Geant4 for X-ray production and detection in the radiodiagnostic energy range
Keywords in English
Medical physics
Monte Carlo method
X-ray production
X-ray spectroscopy.
Abstract in English
The aim of this work was the validation of a computational tool applied in simulations of electrons and X ray interactions with matter, using the Monte Carlo method for possible studies in diagnostic radiology. To perform this task, a computational program was developed to simulate the radiation production of a X ray equipment, with the purpose of obtaining the photon energy distribution which comprehends the region of interest, without the necessity of experimental measurements. Another task carried through in this work was the calculation of a CdTe detector response, which was used in the correction of measured spectra with energy distribution typically found in diagnostic radiology. The employed computational tool was Geant4, which is a free distribution set of computational programs used for simulation of the passage of particles through matter. One of the main differentials of Geant4 is the exploitation of advanced software-engineering techniques and object-oriented technology. The results of the simulation of energy spectra produced by a X ray equipment show that Geant4 can be used for this application, but with restrictions concerning the simulation of X ray spectra from molybdenum targets in the mammography energy range. This is the situation where the differences of the characteristic X ray yield between the simulated and reference spectra are more pronounced. For the simulation of X ray measurements with a CdTe detector, the results showed excellent agreement with the reference data. In this case the discrepancies must be originated mainly by effects of charge trapping and the nonuniformity of the electric field inside the CdTe crystal. In resume, the validation of the Geant4 carried through in this work showed some of the possibilities for the use of this versatile tool in diagnostic radiology.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2007-09-11
 
WARNING: The material described below relates to works resulting from this thesis or dissertation. The contents of these works are the author's responsibility.
  • MORALLES, M, et al. Monte Carlo and least-squares methods applied in unfolding of X-ray spectra measured with cadmium telluride detectors [doi:10.1016/j.nima.2007.05.147]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detector [online], 2007, vol. 580, n. 1, p. 270-273.
  • MORALLES, Maurício, et al. Applications of the Monte Carlo method in nuclear physics using the GEANT4 toolkit [doi:10.1063/1.3157829]. In AIP Conference Proceedings [online], São Sebastião, São Paulo, . São Sebastião, São Paulo : AIP, 2009. p. 51-56.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.