• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.43.1998.tde-13082002-100046
Document
Auteur
Nom complet
Marcelo Martinelli
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 1997
Directeur
Jury
Horowicz, Ricardo Josue (Président)
Lejbman, Iuda Dawid Goldman Vel
Vieira Junior, Nilson Dias
Titre en portugais
Medida de efeitos óticos não-lineares por reflexão de luz polarizada.
Mots-clés en portugais
efeito Kerr ótico
RZ-scan
varredura Z
Z-scan
Resumé en portugais
Apresentamos neste trabalho uma nova técnica de medida dos termos não-lineares do coeficiente de absorção (beta) e do índice de refração (n_2). Esta nova técnica, denominada Varredura Z de Reflexão Inclinada, aumenta a sensibilidade da Varredura Z de Reflexão em cerca de 30 vezes pelo emprego de um feixe polarizado com incidência inclinada sobre a amostra em estudo. Para uma polarização paralela ao plano de incidência, temos um máximo de sensibilidade nas proximidades do ângulo de Brewster para materiais transparentes, ou do ângulo de mínima reflexão em materiais absortivos. Conseguimos por este método medir variações do índice de refração da ordem de 10^{-4} em absorvedores saturáveis (Aluminato de Gadolínio - GdAlO_{3}:Cr^{+3}). Tais medidas não seriam possíveis sem o aumento obtido na sensibilidade e o uso de uma alta resolução no sistema de aquisição (melhor que 0,1% em intensidade).
Titre en anglais
Measurement of non-linear optical effects through the reflection of polarized light.
Mots-clés en anglais
optical Kerr effect
Resumé en anglais
We present in this work a new technique that we developed for the measurements of nonlinear coefficients of the absorption (beta) and from the refractive index (n_2). The use of a polarized beam in this new technique (Reflection Z-Scan with Inclined Incidence) increases the set-up sensibility of the conventional RZ-Scan measurement in 30 times. For parallel polarization of the beam to the incidence plane, we can see an increase in the measurement sensibility as the incident light angle approaches the Brewster angle for transparent materials, or the minimum reflection angle for an absorbing material. We have measured changes in the refractive index as small as 10^{-4} in saturable absorber (Gadolinium Aluminate - GdAlO_{3}:Cr^{+3}). Such measurements would not be possible without the development of the sensitivity enhancement achieved by this technique and a high amplitude resolution on the data acquisition system, as small as 0.1%.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Mestrado.pdf (971.14 Kbytes)
Date de Publication
2002-08-23
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.