Tesis Doctoral
DOI
https://doi.org/10.11606/T.43.1991.tde-28022014-152306
Documento
Autor
Nombre completo
Manfredo Harri Tabacniks
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 1991
Director
Tribunal
Orsini, Celso Maria de Queiroz (Presidente)
Baumvol, Israel Jacob Rabin
Lejbman, Iuda Dawid Goldman Vel
Vasconcellos, Marina Beatriz Agostini
Vieira, Carlos
Título en portugués
Desenvolvimento de metodologia para análise de filtros de fibras de vidro pelo método PIXE
Palabras clave en portugués
Filtros de fibras de vidro
Física nuclear
Poluição do ar
Resumen en portugués
Foi desenvolvida e testada metodologia de extração seletiva diferencial de material particulado do aerossol atmosférico, coletado em filtros de fibras de vidro, para análise elementar pelo método PIXE. Desenvolveu-se um procedimento para a correção absoluta de efeitos de autoabsorção de raios x em alvos pipetados. Amostras de material particulado foram coletadas com amestradores HiVol em São Paulo e no Rio de Janeiro. Foi determinada a composição elementar das frações do material particulado total solúveis em diclorometano, água e uma mistura de ácidos nítrico e clorídrico,1N. Os limites de detecção alcançados pela técnica de extração, pipetagem e análise PIXE foram de 5 a 30 vezes inferiores aos dos filtros Nuclepore. Foram quantificados de 10 a 14 elementos traço em compostos apolares, em concentrações tão baixas quanto 10pg/'m POT. 3' e 24 elementos em cada uma das frações solúvel em água e ácido. Não se pode desprezar efeitos de autoabsorção de raios x em alvos pipetados. Mesmo em alvos tão finos quanto 100'mü'g/c'm POT. 2', a concentração de elementos com Z<20 pode ser seriamente subestimada. Sugere-se sempre determinar as espessuras e coeficientes de absorção de Massa dos a l vos pelo método dos dois alvos pipetados com soluções com concentrações diferentes desenvolvido neste trabalho. Historicamente o método PIXE tem sido divulgado como permitindo a análise direta de amostras sem nenhum tratamento prévio. É hora de rever esta afirmação e aumentar a quantidade e qualidade de informação na análise elementar de uma amostra, aliando a informação química à da composição elementar.
Título en inglés
Development of a methodology for analysis of glass fiber filters by the PIXE method
Palabras clave en inglés
Nuclear physics
Nuclear physics (instrumentation)
Resumen en inglés
PIXE analysis of particulated matter in glass fibre filters was done on pippeted targets, prepared with solutions of differential and selective extracts from the filters. An x ray autoabsorption correction method, based on the analysis of targets pipetted with solutions of different concentrations, was developed. São Paulo and Rio de Janeiro aerosol samples were collected on normal glass fibre filters by HiVol samplers. The elementary composition of aerosol particulated matter soluble in dichloromethane, water and a mixture of nitric and hidrochloricacid, 1N, was determinated. PIXE analysis detection limits, of the measured concentrations, where 5 to 30 times lower than the achieved by samples on Nuclepore filters. There has been quantified 10 to 14 elements in the dichloromethane fraction, and 24 in each, water and acid soluble fractions. X ray autoabsorption effects cannot be neglected, even on targets as thin as 100'mü'g/c'm POT. 2'. It is suggested to apply the developed two concentration pippeted target method, to measure target thickness and to correct data for autoabsorption. It is claimed for long time that PIXE analysis of aerosol samples is a quick and straightforward analytical method where it is not necessary to prepare samples. Reviewing this use will provide the addition of chemical information to elementary PIXE results.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
46149Tabacniks.pdf (87.12 Mbytes)
Fecha de Publicación
2014-02-28
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.