• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.39.2007.tde-08082008-163407
Document
Auteur
Nom complet
Fábio Micolis de Azevedo
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2007
Directeur
Jury
Alves, Neri (Président)
Gonçalves, Mauro
Mochizuki, Luis
Negrão Filho, Ruben de Faria
Serrão, Julio Cerca
Titre en portugais
Avaliação do sinal eletromiográfico como parâmetro para determinação do limiar de fadiga muscular
Mots-clés en portugais
biomecânica
eletromiografia
fadiga muscular
limiar de fadiga eletromiográfico
músculo quadríceps
Resumé en portugais
Embora a analise no domínio da freqüência do sinal Eletromiográfico (EMG) seja empregada na caracterização do processo de fadiga muscular localizada sua aplicação, especificamente a da Freqüência Mediana (Fmed), é pouco explorada para a determinação do Limiar de Fadiga Eletromiográfico (LFE). Neste estudo foram realizadas análises baseadas em procedimentos experimentais executados em três diferentes modalidades de exercício: i) isométrico; ii) isotônico com peso fixo; iii) isotônico no cicloergômetro; onde foi monitorado o comportamento da Fmed do sinal EMG em três porções do músculo quadríceps femoral: vasto lateral, vasto medial e reto femoral. Os resultados demonstraram ser possível determinar o LFE através da monitoração da Fmed, em qualquer modalidade de exercício para todas as três porções musculares avaliadas. Entretanto, para o exercício isométrico e isotônico com peso fixo a qualidade dos ajustes, utilizados para o calculo do LFE, apresentou melhores índices estatísticos em comparação com os resultados obtidos no cicloergômetro. Pode ser considerado um reflexo deste comportamento a menor variação nos valores do LFE observada nas duas primeiras modalidades de exercício. Por conseqüência, nestas modalidades, uma melhor caracterização do LFE, relacionada sua definição teórica, foi observada. A análise complementar das bandas de freqüência isoladas demonstrou a possibilidade de melhoramentos relacionados ao processo metodológico de tratamento do sinal EMG para determinação do LFE. Entende-se que a determinação do LFE é uma temática controversa, porém ao mesmo tempo apresenta um grande potencial de exploração científica caracterizando, neste contexto, a contribuição deste estudo para a área
Titre en anglais
Evaluation of the eletromyographic signal as paameter for determination of muscle fatigue threshold
Mots-clés en anglais
Biomechanics
Electromiography
Electromyographic fatigue threshold
Muscle fatigue
Quadriceps muscle
Resumé en anglais
Tthough the analysis in the frequency domain of the Electromyographic Signal (EMG) was used in the characterization of the localized muscular fatigue process their application, specifically the Median Frequency (MF), is rarely explored for the determination of Electromyographic Fatigue Threshold (EMGFT). In this study analysis based in experimental procedures were executed in three different modalities of exercise: i) isometric; ii) dynamic with fixed load; iii) dynamic in the cycle ergometer; where was monitored the behavior of the EMG signal through the MF in three portions of the quadriceps muscle: vastus lateralis, vastus medialis and rectus femoris. The results demonstrated that the determination of EMGFT through the monitorization of MF was possible, in any modality of exercises for all the three muscular portions evaluated. However for the isometric and dynamic exercise with fixed load the quality of the adjustments, used for estimate the EMGFT, presented better statistical index in comparison with the results obtained in the cycle ergometer. May be considered a reflex of this behavior the smallest variation in the values of EMGFT observed in the first two modalities of exercise. For consequence, in these modalities, a better characterization of EMGFT was observed when related with your theoretical definition. The complemental analysis of the isolated bands of frequency demonstrated the possibility of improvement related in the methodological process of EMG signal processing for determination of EMGFT. The understanding around the determination of EMGFT demonstrated a controversial theme, however at the same time it presents a great potential of scientific exploration characterizing, in this context, the contribution of present study for this area
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
micolis.pdf (2.19 Mbytes)
Date de Publication
2008-08-11
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.