• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.39.1992.tde-13122023-154711
Document
Auteur
Nom complet
Maria Urbana Pinto Brandão Rondon
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 1992
Directeur
Jury
Negrão, Carlos Eduardo (Président)
Hironaka, Fausto Haruki
Wajngarten, Mauricio
Titre en portugais
Estudo da fração de ejeção do ventrículo esquerdo durante exercício dinâmico em indivíduos sedentários e treinados
Mots-clés en portugais
Exercício físico
Indivíduos sedentários
Ventrículo esquerdo
Resumé en portugais
Muitos autores têm estudado o efeito agudo do exercício físico sobre a função ventricular esquerda. Entretanto, existem poucos dados relacionando o impacto metabólico do exercício sobre a função ventricular. Os objetivos desta investigação foram: 1. estudar o efeito do impacto metabólico provocado pelo exercício físico dinâmico na função ventricular esquerda; e 2- estudar o efeito do treinamento físico sobre a função ventricular esquerda no repouso (Rep), no limiar anaeróbio (Lan) e no pico do exercício (PE) no homem. Doze sedentários sadios (S, 30 ± 3 anos) e treze treinados sadios (T, 26 ± 4 anos) submeteram-se à ecodopplercardiografia de repouso e à cintilografia sincronizada das câmaras cardíacas, no repouso e durante exercício: em cicloergômetro na posição semi sentada, com incrementos de carga de 25 W a cada seis minutos até a exaustão. Foram utilizadas análises de variância de dois caminhos para medidas repetidas e comparações post-hoc de Scheffé. A fração de ejeção aumentou significativamente no Lan e no PE em relação ao Rep (80 ± 5,3; 83,6 ± 5,5 vs. 66 ± 5,9%, respectivamente), mas não foi observada diferença significativa entre os grupos. A contagem diastólica máxima diminuiu em ambos os grupos no Lan (S= 9,1 ± 12,6; T= - 7,3 ± 17,8%) e no PE (S= -14,1 ± 12,8; T= -7,7 ± 23,7%). A contagem sistólica mínima diminuiu significativamente no Lan (S= -41,1 ± 15,4; T= -46,1 ± 17%) e no PE (S= -50,5 ± 15,3; T= -55,2 ± 19,7%), mas não foi observada diferença significativa entre os grupos. O volume diastólico final, no repouso, foi significativamente maior no grupo T que no grupo S (153,5 ± 33,3 vs. 123,3 ± 26,4 ml). O volume sistólico final, no repouso, não foi estatisticamente diferente entre os grupos (S= 31,3 ± 7,7 vs. T= 36,3 ± 9,4 ml). O volume sistólico, no repouso, foi significativamente maior no grupo T que no grupo S (117,2 ± 30,7 vs. 92,1 ± 20,1 ml). Em conclusão: 1. a fração de ejeção aumentou significativamente mesmo após o Lan; 2. o treinamento físico não modificou o comportamento da fração de ejeção no Rep, Lan e PE; e 3. o volume diastólico final, no repouso, determinou o maior volume sistólico no T e este comportamento é mantido durante o exercício físico
Titre en anglais
Study of left ventricular ejection fraction during dynamic exercise in sedentary and trained subjects
Mots-clés en anglais
Left ventricle
Physical exercise
Sedentary individuals
Resumé en anglais
Many investigators have studied the acute effect of exercise on the left ventricular function. However, there are few available data relating the metabolic impact of exercise on the left ventricular function. The aims of this present investigation were: 1- to study the effect of the metabolic impact caused by the dynamic exercise on the left ventricular function, and 2- to study the effect of exercise training on the left ventricular function at rest (R), anaerobic threshold (AT) and peak of exercise (PE) in men. Twelve healthy sedentary (S, 30 ±3 years) and thirteen trained (T, 26 ± 4 years) men underwent to an ecodopplercardiographic evaluation at rest and a gated blood pool scintigraphy at rest and during exercise, in cycle ergometer in semi-sitting position, with workload increments of 25 W every six minutes up to exhaustion. A twowa/ analysis of variance with repeated measures and ScheffA post-hoc comparisons were performed. The ejection fraction significantly increased at AT and PE as compared to R (80 ± 5.3; 83.8 ± 5.5 vs. 66 ± 5.9%, respectively), but it was not statistically different between groups. The maximal diastolic counts decreased in both groups at AT (S= -9.1 ± 12.6; T= -7.3 ± 17.8%) and PE (S= -14.1 ± 12.8; T= -7.7 ± 23.7%). The minimal systolic counts significantly decreased at AT (S= -41.1 ± 15.4; T= -46.1 ± 17%) and PE (S= -50.5 ± 15.3; T= -55.2 ± 19.7%) but no significant difference was observed between groups. The end diastolic volume was significantly higher in the T than S (153.5 ± 33.3 vs. 123.3 ± 26.4 ml) group. The end systolic volume was not statistically different between groups at rest S= 31.3 ±7.7 vs. T= 36.3 ± 9.4 ml). The stroke volume was significantly higher in the T than S (117.2 ± 30.7 vs. 92.1 ± 20.1 ml) group. In conclusion: 1- the ejection fraction significantly increased even after the AT; 2- exercise training did not modify the ejection fraction at R, AT and PE and, 3- the end diastolic volume at rest determined the higher stroke volume in the T group and this behavior is maintained during exercise
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2023-12-14
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.