Leitura automática de dispositivos mostradores analógicos de instrumentos de medição utilizando visão computacional.
Keywords in Portuguese
Calibração automática
Instrumento de medida
Leitura automática
Visão computacional
Abstract in Portuguese
Propõe-se um sistema de visão computacional para leitura automática de dispositivos mostradores analógicos de instrumentos de medição que não possuem interface de comunicação digital. Esse sistema pode ser aplicado na automação de processos de calibração desses instrumentos ou em outros ensaios em que sejam feitas leituras repetitivas por um operador humano. Espera-se reduzir o tempo de leitura e os custos envolvidos nos processos e alcançar exatidão e incerteza ao menos equivalentes aos da leitura humana. A abordagem proposta se baseia na comparação da inclinação do ponteiro com as inclinações das marcas de escala do dispositivo mostrador. Em uma primeira etapa realiza-se o reconhecimento das marcas de escala e a correspondência de cada marca a um valor de leitura a partir de três imagens capturadas e algumas informações consideradas conhecidas como o número de escalas, o número de marcas principais por escala e os valores associados a essas marcas principais. Em seguida parte-se para uma segunda etapa em que para cada nova imagem capturada é obtido um valor de leitura por meio da interpolação entre valores de inclinações calculados e os valores de leitura associados às marcas de escala. Uma análise de incerteza de leitura mostra que para os instrumentos estudados e equipamentos empregados (câmera e lentes) a leitura automática é compatível com a leitura humana e que a incerteza poderia ser eventualmente melhorada. Foram realizados diversos testes de leitura automática. Os resultados obtidos confirmaram as expectativas de incertezas e a ocorrência de erros mais significativos foi da ordem de apenas um por cento o que revela a robustez do método para utilização real.
Title in English
Automatic reading of measurement devices analogical displays using computer vision.
Keywords in English
Automatic calibration
Automatic reading
Abstract in English
A computer vision system for automatic reading of measurement devices analogical displays which do not have a digital communication interface is proposed. This system could be applied for the automation of these devices calibration processes or in other assays in which repetitive readings are done by man. It is expected a reduction in time spent and costs involved and an achievement of accuracy and uncertainty at least equivalent to those attained in human readings. The approach is based on the comparison between the pointer slope and the display device scale marks slope. In a first step the scale marks are identified and a reading value is attributed to each mark from three captured images and some assumed known data as the number of scales, the number of the main marks per scale and the corresponding values associated with these main marks. Then, in a second step, an reading value is attained to each new captured image through the interpolation between the calculated slopes figures and the associated marks reading values. An reading uncertainty analysis shows that considering the studied instruments and the employed devices (camera and lens) the automatic reading is consistent with the human reading and the uncertainty could be eventually improved. Several automatic reading tests were carried out. The results confirmed the expectations of uncertainties and the meaningful error rate was about only one per cent revealing the methods robustness to real application.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2017-03-28
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.